After replacing the power distribution board of the chassis
▶
Check the SEL log file to verify whether the system information for the
chassis has been restored, see
"Viewing and clearing the System Event
Chassis IDPROM: BMC FW backup successful
Automatic restore of chassis FRU data from backup file
finished successfully.
▶
If the restore is not successful, the following System Event Log (SEL) is
logged, see
"Using the Chassis ID Prom Tool" on page 96
to restore
system information.
Automatic restore of chassis FRU data from backup file
failed.
5.2.2
Performing a RAID array rebuild
After replacing an HDD that has been combined into a RAID array, RAID
rebuild will be performed completely unattended as a background process.
▶
Ensure that the RAID array rebuild has started normally. Wait until the
progress bar has reached at least one percent.
▶
Inform the customer about the remaining rebuild time, based on the
displayed duration estimate.
Basic software procedures
CX400 M6
Upgrade and Maintenance Manual
89