FAN indicator (1)
Status
Description
off
The corresponding fan module has failed.
Lights up orange
The corresponding fan module is OK.
13.2.2.3
Indicators of the server nodes
For the description of the indicators of the server nodes, see the
operating manuals of the relevant server nodes.
13.3
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
1 Server node
CX2550 M6 or
CX2560 M6
1 PSU
Table 10: Minimum startup configuration - components
Cable
Notes
Power cable
Table 11: Minimum startup configuration - cables
Appendix A
204
Upgrade and Maintenance Manual
CX400 M6