![Fujitsu PRIMERGY CX400 M6 Скачать руководство пользователя страница 203](http://html.mh-extra.com/html/fujitsu/primergy-cx400-m6/primergy-cx400-m6_upgrade-and-maintenance-manual_121047203.webp)
PSU status indicator (1)
Status
Description
flashing green
The server is switched off, but it is connected to the
mains (standby mode).
green on
The server is switched on and operating properly.
flashing orange
Warning has been detected. The PSU is still running, but
failure might be imminent.
orange on
A PSU failure has been detected.
Possible causes:
– The power supply is failing.
– The power supply is not receiving input power when
AC is supplied to one power supply in a redundant
configuration.
13.2.2.2
Fan indicators
Figure 167: Fan indicators
1
FAN indicator
Appendix A
CX400 M6
Upgrade and Maintenance Manual
203