CX400 M4
Operating Manual
27
Product description
3.3.1.3
Indicators on the hot-plug HDD/SSD module
Figure 8: Indicators on the 2.5 inch HDD modules
Pos. Label
Indicator
Status
Description
1
Access
indicator
off
The HDD/SSD is inactive.
green on The HDD/SSD being accessed
2
Error
indicator
off
No HDD/SSD error detected.
orange
on
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and
needs replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
flashing
orange
slowly
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has
been combined into a RAID array.
!
Содержание PRIMERGY CX400 M4
Страница 6: ...Operating Manual CX400 M4 ...
Страница 10: ...10 Operating Manual CX400 M4 Introduction ...
Страница 14: ...14 Operating Manual CX400 M4 Before you start ...
Страница 42: ...42 Operating Manual CX400 M4 Important information ...
Страница 71: ...CX400 M4 Operating Manual 71 Operation This is the good case This is the bad case gap under the bracket ...
Страница 74: ...74 Operating Manual CX400 M4 Operation ...
Страница 82: ...82 Operating Manual CX400 M4 Technical data ...
Страница 84: ...84 Bearbeitungsstand Bestellnummer Warranty and service ...