218
Upgrade and Maintenance Manual
CX2550 M1
Appendix
12.2.2.3 Global error indicator, ID indicator, CSS indicator
Global error indicator (orange)
–
Lights up orange
if a prefailure event has been detected that
requires (precautionary) service intervention.
–
Flashes orange
if an error was detected that requires service
intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the ServerView Operations Manager or via
the iRMC S4's Web interface.
ID
ID indicator (blue)
Lights up blue when the system has been selected by pressing
the ID button. To deactivate, press the button again.
The ID indicator can also be activated via the ServerView
Operations Manager and the iRMC S4 Web interface and its
status reported to the ServerView Operations Manager and the
iRMC S4.
CSS indicator (orange)
–
Lights up orange
if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of precaution)
with the CSS concept.
–
Flashes orange
if an error was detected that you can fix
yourself with the CSS concept.
–
Does not light up
when the supervised components are OK.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
!
Содержание PRIMERGY CX2550 M1
Страница 14: ...Upgrade and Maintenance Manual CX2550 M1 Contents ...
Страница 52: ...52 Upgrade and Maintenance Manual CX2550 M1 Basic hardware procedures ...
Страница 90: ...90 Upgrade and Maintenance Manual CX2550 M1 Basic software procedures ...
Страница 204: ...204 Upgrade and Maintenance Manual CX2550 M1 Liquid cooling ...
Страница 210: ...210 Upgrade and Maintenance Manual CX2550 M1 Cabling ...
Страница 222: ...222 Upgrade and Maintenance Manual CX2550 M1 Appendix ...