23
REFRIGERANT REPLENISHMENT
Every unit is prefilled by R410A refrigerant. It is not necessary to replenish any refrigerant. In a case of refrigerant leak and loss, add
necessary amount according to the external unit label or according to this table.
Neoré 14, 16
Neoré ..HP
Neoré 8, 11
3,35 kg
2,5 kg
1,7 kg
Model
Fill of regrigerant
3
This air conditioner uses new refrigerant HFC (R410A).
The instalation of the device is the same like instalation of devices with R22, R407, R134 refrigerant etc.
It´s necessary to keep these rules:
1
The pressure is about 1,6x higher than pressure with convectional refrigerants. Therefore is necessary to use
special instruments and measure equipment. It´s necessary to use copper pipeline with homologation for R410A
refrigerant for connection of inside and outside unit. If you work with refrigeration technology, you should
use protective equipment such as glasses, gloves etc.
2
This device with R410A refrigerant uses different service connection from convection refrigerants, which prevents
against connection of unapproved service tool. The connection for R410A refrigerant is 1/2 UNF (standard R410
accessories).
3
Don´t use pipeline which was used with another refrigerant or lubricating oil. The pipeline must be extremely clean
and dry. Storage and transportation of pipeline must be in closed state.
4
Filling and exchange of refrigerant must be in liquid state when the refrigerant is stable and both parts are added in
the correct ratio. The R410A refrigerant consists of two parts.
This device contains new HFC refrigerant (R410A)
4
Содержание NEORE 11
Страница 1: ...User manual Installation instruction Heat Pump Neoré 08 2016 All rights and changes reserved F ...
Страница 6: ...5 ...
Страница 42: ...41 ...