WARNING
1
Install only according to this manual.
2
Connect inside and outside unit (refrigerant, electric) only by using the material mentioned in the manual.
3
Installation of refrigerant and electrical circuit can be performed only by authorized persons.
4
Don´t use flexible cords and pipelines for the units connection.
5
Don´t run the device which is not completely installed.
6
Don´t use refrigerant of unknow quality and cleanliness. Keep the safety rules.
7
Don´t add refrigerant to boost of output power.
8
Always use the vacuum pump before you fill refrigerant.
9
Respect work safety and use protective equipment during installation.
65 cm
50 cm
65 cm
min 30 cm
500 mm
100 mm
PLACEMENT AND INSTALLATION
The heat pumo must install professional company authorised by manufacturer. Do not try it yourself.
It may lead to device destruction or injury to persons.
The indoor unit will hang on the wall fixed to mounting plate. It´s placement must be done considering possible
access to regulatory and protective devices and for service. See picture below. The outdoor unit will be screwed to
the pedestal. The pedestal is necessary for the effective defrosting. This pedestal must be securely attached to
the concrete pad. The pad should have the size which excludes the overturn of the unit during windy weather.
The placement should not inhibit the air flow and also alllows service and repair access. The placement in dense
development must be chosen so that fan noise meets noise standards. In some cases is suitable to make noise
test.
environment by ČSN 33 2000-3 for outdoor unit AA2-AA5; AB7; AD3
environment by ČSN 33 2000-3 for indoor unit
AA5; AB5