5.5 Checking Operation after Installation and Preparing the IDD for Use
C141-E198
5-15
(3) Caching
parameters
The following parameters are used to optimize IDD Read-Ahead caching operations under the system
environments. Refer to Chapter 2 of Fibre Channel Interface Specifications for further details.
Parameter
Default
value
• IC:
Initiator control
0 (Drive-specific
control (page
cache))
• RCD:
Disabling Read-Ahead caching operations
0 (enabled)
• WCE:
Write Cache Enable
1 (enabled)
• MS:
Specifying the multipliers of "minimum
prefetch" and "maximum prefetch" parameters
0
(Specifying
absolute value)
• DISC:
Prefetch operation after track switching during
prefetching
1
(enabled)
• Number of blocks for which prefetch is suppressed
X'FFFF'
• Minimum prefetch
X'0000'
• Maximum prefetch
X' XXXX'
(1 cache segment)
• Number of blocks with maximum prefetch restrictions
X'FFFF'
• Number of segments
X'08'
Notes:
1.
When Read-Ahead caching operations are disabled by the caching parameter, these
parameter settings have no meaning except write cache feature.
2.
Determine the parameters in consideration of how the system accesses the disk. When the
access form is not determined uniquely because of the processing method, the parameters
can be re-set actively.
3.
For sequential access, the effective access rate can be increased by enabling Read-Ahead
caching operations and Write Cache feature.
(4)
Control mode parameters
The following parameters are used to control the tagged queuing and error logging.
Содержание MAS3367FC
Страница 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 8: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 20: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Страница 70: ...Installation 5 8 C141 E198 Motor starts when power is turned on Figure 5 1 Checking the IDD connection A 60 ...
Страница 108: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 113: ......
Страница 114: ......