Error Analysis
7-4
C141-E198
7.2.2
Sense data (3-0C-03), (4-40-xx), (4-44-xx), and (4-C4-xx)
Sense data (3-0C-03), (4-40-xx), (4-44-xx), and (4-C4-xx) indicate one of the following:
•
A target sector could not be detected using the sector counter.
•
A seek process overran the specified time.
•
A write to a disk terminated abnormally.
•
An error occurred in power-on self-diagnosis.
•
A hardware error occurred inside IDD.
•
A drive error occurred.
The symptoms above are generally caused by an error in a PCA or DE.
For details of the sense data above, refer to the Fibre Channel Interface Specifications.
7.2.3
Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error
If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, there
is disk damage that was not recorded in the media defect list. In this case, assign an alternate block
to the error-detected block using a REASSIGN BLOCKS command. For an explanation of the
REASSIGN BLOCKS command, refer to the Fibre Channel Interface Specifications.
If this error occurs in different blocks, a PCA or DE is faulty.
For details of the above sense data, refer to the Fibre Channel Interface Specifications.
7.2.4
Sense data (5-2x-xx), (5-3D-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00): fibre channel
interface error
Sense data (5-2x-xx), (5-3D-00), (B-47-xx), (B-49-00), (B-4D-xx) and (B-4E-00) indicates one of
the following symptoms:
•
An invalid or unsupported command was issued, or invalid or unsupported parameters were
specified.
•
A SCSI error occurred.
•
A CRC error occurred in the fibre channel loop.
If this error occurs, a PCA or the fibre channel interface is faulty.
For details of the above sense data, refer to the Fibre Channel Interface Specifications.
Содержание MAS3367FC
Страница 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 8: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 20: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Страница 70: ...Installation 5 8 C141 E198 Motor starts when power is turned on Figure 5 1 Checking the IDD connection A 60 ...
Страница 108: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 113: ......
Страница 114: ......