Specifications
2-2
C141-E198
2.1.2 Function
specifications
Table 2.2 shows the function specifications of the IDD.
Table 2.2
Function specifications
Specification
Item
MAS3735FC MAS3367FC
Formatted capacity/device (*1)
73.49 GB (*6)
36.77 GB (*6)
Number of disks
4
2
Number of heads
8
4
Number of cylinders (*2)
27,094
27,150
Formatted capacity/track (B)
285,696 to 360,960
Number of rotations min
-1
(rpm)
15,000 ± 0.2%
Average latency time
2.00 msec
Track to Track
0.3 ms/0.5 ms
Average
3.3 ms/3.8 ms
Seek time (*3)
(Read/Write)
Full stroke
8.0 ms/9.0 ms
Start/stop time
(*4)
Start time
Stop time
30 s typ. (60 s max.)
30 s typ.
Recording mode
32/34 MEEPRML
External
dimensions
Height:
Width:
Depth:
25.4 mm
101.6 mm
146.0 mm
Weight (max)
0.80kg
Power consumption (*5)
13.0 W
10.2 W
Interface
Cable length: 30 m max
Disk drive
93.11 to 118.22 MB/s
Data
transfer
rate
FC-AL
212.5 MB/s max.
Logical data block length
512 to 528 byte (Fixed length)
Command specification
FC-PLDA (NCITS TR-19),
FC-PH (ANSI X3.230-1994), FC-PH-2 (ANSI X3.297-1996),
FC-AL (ANSI X3.272-199X), SCSI-FCP (ANSI X3.269-199X)
Data buffer
32 MB FIFO ring buffer (*7)
Acostic noise (Ready)
3.6 Bels typ. (4.1 Bels max.)
(*1)
The formatted capacity can be changed by changing the logical block length and using spare sector
space. See Chapter 3 for the further information. The formatted capacity listed in the table is an
estimate for 512 bytes per sector.
(*2)
The number of user cylinders indicates the max., and includes the alternate cylinder. The number of
user cylinders and alternate cylinders can be specified at format of the IDD.
(*3)
The positioning time is as follows:
Содержание MAS3367FC
Страница 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 8: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 20: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Страница 70: ...Installation 5 8 C141 E198 Motor starts when power is turned on Figure 5 1 Checking the IDD connection A 60 ...
Страница 108: ...This page is intentionally left blank ...
Страница 110: ...This page is intentionally left blank ...
Страница 112: ...This page is intentionally left blank ...
Страница 113: ......
Страница 114: ......