C141-E035-02EN
5 - 20
5.6.4
Setting parameters
The user can specify the optimal operation mode for the user system environments by setting
the following parameters with the MODE SELECT or MODE SELECT EXTENDED
command:
•
Error recovery parameter
•
Disconnection/reconnection parameter
•
Caching parameter
•
Control mode parameter
With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP"
bit on CDB to save the specified parameter value on the disk. This enables the IDD to operate
by using the parameter value set by the user when power is turned on again. When the system
has more than one INIT, different parameter value can be set for each INIT.
When the parameters are not set or saved with the MODE SELECT or MODE SELECT
EXTENDED command, the IDD sets the default values for parameters and operates when
power is turned on or after reset. Although the IDD operations are assured with the default
values, the operations are not always optimal for the system. To obtain the best performance,
set the parameters in consideration of the system requirements specific to the user.
This section outlines the parameter setting procedures. Refer to Chapter 3 of SCSI Logical
Interface Specifications for further details of the MODE SELECT and MODE SELECT
EXTENDED commands and specifying the parameters.
IMPORTANT
1.
At factory shipment of the IDD, the saving operation for the MODE
SELECT parameter is not executed. So, if the user does not set
parameters, the IDD operates according to the default value of each
parameter
2.
The model select parameter is not saved for each SCSI ID of but as
the common parameter for all IDs. In the multi-INIT System,
parameter setting cannot be changed for each INIT.
3.
Once parameters are saved, the saved value is effective as long as
next saving operation is executed from the INIT. For example, even if
the initialization of the disk is performed by the FORMAT UNIT
command, the saved value of parameters described in this section is
not affected.
4.
When the IDD, to which the saving operation has been executed on a
system, is connected to another system, the user must pay attention to
that the IDD operates according to the saved parameter value if the
saving operation is not executed at installation.
Содержание MAA3182
Страница 3: ......
Страница 21: ...C141 E035 02EN 1 6 Figure 1 2 MAA31xxSP outer view Figure 1 3 MAB30xxSC outer view ...
Страница 27: ......
Страница 35: ......
Страница 53: ...C141 E035 02EN 4 2 Figure 4 1 External dimensions MAA31xxSC ...
Страница 54: ...C141 E035 02EN 4 3 Figure 4 2 External dimensions MAA31xxSP ...
Страница 55: ...C141 E035 03EN 4 4 Figure 4 3 External dimensions MAB30xxSC MAC30xxSC ...
Страница 56: ...C141 E035 03EN 4 5 Figure 4 4 External dimensions MAB30xxSP MAC30xxSP ...
Страница 68: ...C141 E035 02EN 4 17 Figure 4 20 External operator panel connector CN7 ...
Страница 83: ...C141 E035 01EN 5 4 3 Connecting more than one IDD multi host Figure 5 1 SCSI bus connections 2 of 2 ...
Страница 85: ...C141 E035 02EN 5 6 Figure 5 3 Setting terminals MAx3xxxSP ...
Страница 95: ...C141 E035 02EN 5 16 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A ...
Страница 96: ...C141 E035 02EN 5 17 Motor starts by START STOP command Figure 5 5 Checking the SCSI connection B ...
Страница 111: ...C141 E035 02EN 6 8 At shipment Figure 6 2 Indicating revision numbers Rev A3 Rev A2 Revising at field ...
Страница 115: ......
Страница 119: ......
Страница 123: ......
Страница 135: ......
Страница 139: ......
Страница 140: ......