C141-E035-02EN
4 - 24
4.3.3
Cable connector requirements
Table 4.3 lists the recommended components cable connection.
Table 4.3
Recommended components for connection
Applicable
model
Name
Par number
Manufacturer
Reference
(Figures 4.23
and 4.28)
MAx3xxxSP
SCSI cable (CN1)
Cable socket
(closed-end type)
786090-7
AMP
S1
Signal cable
—
—
Power supply cable
(CN1)
Cable socket
housing
1-480424-0
AMP
S2
Contact
60619-4
Cable
60617-4
External operator
panel (CN1)
Cable socket
housing
FCN-723J012/2M
Fujitsu Limited
S3
Contact
FCN-723J-G/AM
Fujitsu Limited
Cable
AWG26 to 34
External operator
panel (CN7)
Cable socket
housing
FCN-723J016/2M
Fujitsu Limited
S4
Contact
FCN-723J-G/AM
Fujitsu Limited
Cable
AWG28
MAx3xxxSC SCSI connector
(CN1)
Connector
787311-1
AMP
(1)
SCSI cable
All SCSI devices on one bus are daisy-chained with an SCSI cable. A terminating resistor
must be mounted in the SCSI device at each end of the SCSI cable.
Because an SCSI terminating resistor module has been mounted in the IDD of single-ended
type SCSI at factory shipment, it must be set to not-connection when the IDD is not connected
at either end of the SCSI cable. See Section 5.3 for details.
The maximum number of SCSI devices that can be connected to the SCSI bus is 16 for the 16-
bit SCSI, including the host adapter, IDD, and other SCSI equipment.
For the 16-bit SCSI, the connector for the SCSI cable must be an unshielded 68-contact socket
having 34-contact rows spaced 1.27 mm (0.05 inch) apart. (See Figure 4.26.)
Содержание MAA3182
Страница 3: ......
Страница 21: ...C141 E035 02EN 1 6 Figure 1 2 MAA31xxSP outer view Figure 1 3 MAB30xxSC outer view ...
Страница 27: ......
Страница 35: ......
Страница 53: ...C141 E035 02EN 4 2 Figure 4 1 External dimensions MAA31xxSC ...
Страница 54: ...C141 E035 02EN 4 3 Figure 4 2 External dimensions MAA31xxSP ...
Страница 55: ...C141 E035 03EN 4 4 Figure 4 3 External dimensions MAB30xxSC MAC30xxSC ...
Страница 56: ...C141 E035 03EN 4 5 Figure 4 4 External dimensions MAB30xxSP MAC30xxSP ...
Страница 68: ...C141 E035 02EN 4 17 Figure 4 20 External operator panel connector CN7 ...
Страница 83: ...C141 E035 01EN 5 4 3 Connecting more than one IDD multi host Figure 5 1 SCSI bus connections 2 of 2 ...
Страница 85: ...C141 E035 02EN 5 6 Figure 5 3 Setting terminals MAx3xxxSP ...
Страница 95: ...C141 E035 02EN 5 16 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A ...
Страница 96: ...C141 E035 02EN 5 17 Motor starts by START STOP command Figure 5 5 Checking the SCSI connection B ...
Страница 111: ...C141 E035 02EN 6 8 At shipment Figure 6 2 Indicating revision numbers Rev A3 Rev A2 Revising at field ...
Страница 115: ......
Страница 119: ......
Страница 123: ......
Страница 135: ......
Страница 139: ......
Страница 140: ......