C141-E035-03EN
4 - 8
(3)
Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
3 cm from the disk drive. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature does not exceed 55°C.
CAUTION
An air flow with an adequate wind velocity must be maintained to
deal with much heat generated from the MAC30xxxx.
Reference value: An air flow with a wind velocity of more than
0.5 m/s is required in an environment at 40°C,
and an air flow with a wind velocity of more
than 1.0m/s in an environment at 45°C (Center
of DE cover 55°C).
•
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring temperature of specific ICs and the DE. These measurement results
should be within a criteria listed in Table 4.1.
Table 4.1
Surface temperature check point
No.
Measurement point
Criteria
1
Center of DE cover
55°C
2
Read channel LSI
83°C
3
VCM/SPM Driver
75°C
4
HDC
85°C
Figure 4.8
Surface temperature measurement points (MAA31xxxx/MAB30xxxx/ MAC30xxxx)
4
3
2
1
Содержание MAA3182
Страница 3: ......
Страница 21: ...C141 E035 02EN 1 6 Figure 1 2 MAA31xxSP outer view Figure 1 3 MAB30xxSC outer view ...
Страница 27: ......
Страница 35: ......
Страница 53: ...C141 E035 02EN 4 2 Figure 4 1 External dimensions MAA31xxSC ...
Страница 54: ...C141 E035 02EN 4 3 Figure 4 2 External dimensions MAA31xxSP ...
Страница 55: ...C141 E035 03EN 4 4 Figure 4 3 External dimensions MAB30xxSC MAC30xxSC ...
Страница 56: ...C141 E035 03EN 4 5 Figure 4 4 External dimensions MAB30xxSP MAC30xxSP ...
Страница 68: ...C141 E035 02EN 4 17 Figure 4 20 External operator panel connector CN7 ...
Страница 83: ...C141 E035 01EN 5 4 3 Connecting more than one IDD multi host Figure 5 1 SCSI bus connections 2 of 2 ...
Страница 85: ...C141 E035 02EN 5 6 Figure 5 3 Setting terminals MAx3xxxSP ...
Страница 95: ...C141 E035 02EN 5 16 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A ...
Страница 96: ...C141 E035 02EN 5 17 Motor starts by START STOP command Figure 5 5 Checking the SCSI connection B ...
Страница 111: ...C141 E035 02EN 6 8 At shipment Figure 6 2 Indicating revision numbers Rev A3 Rev A2 Revising at field ...
Страница 115: ......
Страница 119: ......
Страница 123: ......
Страница 135: ......
Страница 139: ......
Страница 140: ......