Scanner Interface
Appendix A-72
(a)
Subwindow identifier: Byte 0
Specifies a unique value that identifies a subwindow. If two or more subwindow identifiers
are specified for a single set of subwindow data, the most recently specified identifier is
validated.
9
A
D
E
11
12
6
n
27
28
15
16
17
18
19
1A
1B
1C
1D
1E
Byte 0
1
5
Padding type
(Reserved)
Subwindow identifier
7
6
5
4
3
2
1
0
(MSB)
Upper left X
(LSB)
(MSB)
Width
(LSB)
(MSB)
Length
(LSB)
Brightness
Threshold
Contrast
Image composition
Bit per pixel
Halftone pattern
(MSB)
(LSB)
(Reserved)
RIF
(Reserved)
Vender unique parameter
(MSB)
Upper left Y
(LSB)