Scanner Interface
Appendix A-94
A.4.12 MODE SELECT (6)
The normal sequence related to MODE SELECTE (6) of this scanner is listed below:
Step
Bus phase
Initiator operation
←
→
Target operation
1
Bus Free
Checks Bus Free
2
Arbitration
Acquires right to use
the bus
3
Selection
Selects the target
→
Outputs the BSY signal
4
Message out
Selects the logical
device
→
5
Command
Specifies MODE
SELECT (6) (CDB)
→
Sets up mode data
6
Data In
Specifies MODE
SELECT parameter
data
→
7
Status
←
Reports the GOOD status
8
Message In
←
Reports Command
Complete
Releases the BSY signal
9
Bus Free
(1)
MODE SELECT (6) command: Command phase (Initiator to Target)
This command is used to set up miscellaneous parameters in peripheral devices.
CDB of this command is shown below:
Byte 0
1
2
3
4
5
Operation code X’15’
Logical unit number
(Reserved)
7
6
5
4
3
2
1
0
PF
(Reserved)
SP
Parameter list length
Control byte