TIMER OPERATION

To Cancel the Timer

U s e  t h e T I M E R  M O D E  b u t t o n  t o  s e l e c t  
“CANCEL”.
The air conditioner will return to normal  
operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation while 
the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions 
(mode, fan speed, thermostat setting, QUIET 
mode), after making the timer setting wait until 
the entire display reappears, then press the 
appropriate buttons to change the operating 
condition desired.

To Cancel the Timer

U s e  t h e T I M E R  M O D E  b u t t o n  t o  s e l e c t  
“CANCEL”.
The air conditioner will return to normal  
operation.

To Change the Timer Settings

1.  Follow the instructions given in the sec-

tion “To Use the ON Timer or OFF Timer” to  
select the timer setting you wish to change.

2.  Press the TIMER MODE button to select 

either OFF 

 ON or OFF 

 ON.

To Stop Air Conditioner Operation while 
the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions 
(mode, fan speed, thermostat setting, QUIET 
mode), after making the timer setting wait until 
the entire display reappears, then press the 
appropriate buttons to change the operating 
condition desired.

To Use the ON Timer or OFF Timer

1

  Press the START/STOP button

 

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION indicator lamp (green) will light.

2

  Press the TIMER MODE button to select the OFF timer 

or ON timer operation.

 

Each time the button is pressed the timer function changes in the following 
order:

 

        CANCEL  

 OFF  

 ON

 PROGRAM 

(OFF 

 ON, OFF 

 ON)

 

The indoor unit’s TIMER indicator lamp (orange) will light.

3

  Use the TIMER SET buttons to adjust the desired OFF 

time or ON time.

 

Set the time while the time indicator is flashing (the flashing will continue for 
about 5 seconds).

 button: 

Press to advance the time.

 button: 

Press to reverse the time.

About 5 seconds later, the entire display will reappear.

To Use the Program Timer

1

  Press the START/STOP button

 

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION indicator lamp (green) will light.

2

  Set the desired times for OFF timer and ON timer.

 

See the section “To Use the ON Timer or OFF Timer” to set the desired mode 
and times.

 

About 3 seconds later, the entire display will reappear.

 

The indoor unit’s TIMER indicator lamp (orange) will light.

3

  Press the TIMER MODE button to select the PROGRAM 

timer operation (OFF   ON or OFF   ON will display).

 

The display will alternately show “OFF timer” and “ON timer”, then change to 
show the time setting for the operation to occur first.

M

  The program timer will begin operation. (If the ON timer has been selected 

to operate first, the unit will stop operating at this point.)

 

About 5 seconds later, the entire display will reappear.

About the Program Timer

M

  The program timer allows you to integrate OFF timer and ON timer operations in a 

single sequence. The sequence can involve 1 transition from OFF timer to ON timer, 
or from ON timer to OFF timer, within a 24 hour period.

M

  The first timer function to operate will be the 1 set nearest to the current time.  

The order of operation is indicated by the arrow in the remote controller display  
(OFF 

 ON or OFF 

 ON).

M

  An example of program timer use might be to have the air conditioner automatically 

stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the 
morning before you arise.

Before using the timer function, be sure that the remote controller is set to the correct current time (

 Page 6).

If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the timer.

T

T

T

T

Содержание Inverter ABTG54LR

Страница 1: ...AIR CONDITIONER Ceiling Suspension Type Indoor Unit ABTG54LR OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED PART NO 9374379576 ...

Страница 2: ...h on at least 12 hours before starting the unit M Check the condition of the installation stand for damage M Do not place animals or plants in the direct path of the air flow M Do not drink the water drained from the air conditioner M Do not use in applications involving the storage of foods plants or animals precision equip ment or art works M Do not apply any heavy pressure to radiator fins M Oper...

Страница 3: ...he indoor unit s air filter can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The air filter has been treated to resist mildew growth thus allowing cleaner use and easier care O Remote controller WIRELESS REMOTE CONTROLLER The wireless remote controller allows convenient control of air conditioner operation WIRED REMOTE CONTROLLER OPTION The optional wired remote controller ca...

Страница 4: ...t 3 Remote control signal receiver 4 OPERATION indicator lamp green 5 TIMER indicator lamp orange M TIMER indicator lamp lights when the timer is set from wireless remote controller M If the TIMER indicator lamp flashes when the timer is operating it indicates that a fault has occurred with the timer setting see AUTO Restart on page 17 6 ECONOMY indicator lamp green ECONOMY indicator lamp lights in...

Страница 5: ...e air conditioner s thermostat function to operate incorrectly M If this button is pressed during normal op eration the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously M To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating ...

Страница 6: ...d on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time button...

Страница 7: ...time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the th...

Страница 8: ...in select the appropriate operation heating cooling to adjust the temperature to the value set in the thermostat M If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN Cooling or Dry Defined temperature in temperature setting Heating Determined by outdoor temperature Instructions relating to heating are applicable only to HEAT COOL M...

Страница 9: ...FF time or ON time Set the time while the time indicator is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light...

Страница 10: ... Set time 1 hour 1 C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SL...

Страница 11: ...cle M Adjust the up down left and right air directions with the air direction buttons on the remote controller M Use the air direction buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types o...

Страница 12: ...oner s fan is not operating or when operating at very low speeds M To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green...

Страница 13: ...al code is set to A prior to shipment Contact your retailer to change the signal code M The remote controller resets to signal code A when the batteries in the remote controller are replaced If you use a signal code other than signal code A reset the signal code after replacing the batteries If you do not know the air conditioner signal code setting try each of the signal codes until you find the c...

Страница 14: ...fter washing allow the air filters to dry thoroughly in an area protected from sunlight Air filter Filter Reset ECONOMY indicator lamp flashing The special setting M Can be used if set correctly during installation Please consult authorized serviceman when using this function It lights on when it is time to clean the air filters After turning the power on press the MANUAL AUTO button for 2 seconds or ...

Страница 15: ...oor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted M During cooling or dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden cooling of room air by the air emitted from the air conditioner resulting in condensation and misting M During heating operation the outdoor...

Страница 16: ...stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During automatic defrosting operation the OPERATION indicator lamp green will flash Low Ambient Cooling M When the outdoor temperature drops the outdoor unit s fans may switch to low speed Hot Start for heating M The indoor unit prevents cold drafts when heating operation begins The indoor unit fan will not operate or it ...

Страница 17: ...oller to resume operation AUTO Restart In Event of Power Interruption M During use of the heating mode the top of the indoor unit may become warm but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped it is not a malfunction Notices M During use of the heating mode the outdoor unit will occa sionally commence the defrost operation for brief periods D...