ADJUSTING THE DIRECTION OF AIR CIRCULATION

 DANGER

Never place fingers or foreign objects inside the 
outlet ports, since the internal fan operates at 
high speed and could cause personal injury.

M

Attempting to move up/down air direction 
flaps or right/left air direction louvers man-
ually could result in improper operation; in 
this case, stop operation and restart. The 
louvers should begin to operate properly 
again.

M

During use of the cooling and dry modes, 
do not set the up/down air direction flaps 
in the heating range (

4

 to 

5

) for long 

periods of time, since water vapor may 
condense near the outlet louvers and 
drops of water may drip from the air condi-
tioner. During the cooling and dry modes, 
if the airflow direction louvers are left in 
the heating range for more than 30 mi- 
nutes, they will automatically return to 
position 

3

M

When used in a room with infants, 
children, elderly or sick persons, the air 
direction and room temperature should 
be considered carefully when making 
settings.

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

M

Adjust the up, down, left and right air directions with the air direction buttons on the remote controller. 

M

Use the air direction buttons after the indoor unit has started operating and the airflow-direction louvers have stopped moving.

Vertical Air Direction Adjustment

Press the SET button (Vertical).

Each time the button is pressed, the air direction range will change as follows:

 

1

 

 

2

 

 

3

 

 

4

 

 

5

Types of Airflow Direction Setting:

1

2

3

 

:   During cooling/dry modes

1

2

3

4

5

  :   During heating mode*

The remote controller display does  
not change.

M

Use the air direction adjustments within the ranges shown above.

M

The vertical airflow direction is set automatically as shown, in accordance with the type 
of operation selected.

 Horizontal 

flow 

1

 

:  During cooling/dry mode 

 Downward 

flow 

5

 

:    During heating mode*

M

During AUTO mode operation, for the first minute after beginning operation, airflow will 
be horizontal 

1

; the air direction cannot be adjusted during this period.

Horizontal Air Direction Adjustment

Press the SET button (Horizontal).

Each time the button is pressed, the air direction range will change as follows:

 

1

 

 

2

 

 

3

 

 

4

 

 

5

The remote controller display does  
not change.

M

Use the air direction adjustments within the ranges shown above.

1

2

3

4

5

1 2

3

4 5

Right/left air direction louvers

Содержание Inverter ABTG54LR

Страница 1: ...AIR CONDITIONER Ceiling Suspension Type Indoor Unit ABTG54LR OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED PART NO 9374379576 ...

Страница 2: ...h on at least 12 hours before starting the unit M Check the condition of the installation stand for damage M Do not place animals or plants in the direct path of the air flow M Do not drink the water drained from the air conditioner M Do not use in applications involving the storage of foods plants or animals precision equip ment or art works M Do not apply any heavy pressure to radiator fins M Oper...

Страница 3: ...he indoor unit s air filter can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The air filter has been treated to resist mildew growth thus allowing cleaner use and easier care O Remote controller WIRELESS REMOTE CONTROLLER The wireless remote controller allows convenient control of air conditioner operation WIRED REMOTE CONTROLLER OPTION The optional wired remote controller ca...

Страница 4: ...t 3 Remote control signal receiver 4 OPERATION indicator lamp green 5 TIMER indicator lamp orange M TIMER indicator lamp lights when the timer is set from wireless remote controller M If the TIMER indicator lamp flashes when the timer is operating it indicates that a fault has occurred with the timer setting see AUTO Restart on page 17 6 ECONOMY indicator lamp green ECONOMY indicator lamp lights in...

Страница 5: ...e air conditioner s thermostat function to operate incorrectly M If this button is pressed during normal op eration the unit will switch to test run mode and the indoor unit s OPERATION indicator lamp and TIMER indicator lamp will begin to flash simultaneously M To stop the test run press the START STOP button to stop the air conditioner F Signal transmitter G Temperature SET indicator H Operating ...

Страница 6: ...d on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time button...

Страница 7: ...time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the th...

Страница 8: ...in select the appropriate operation heating cooling to adjust the temperature to the value set in the thermostat M If the mode automatically selected by the unit is not what you wish select one of the mode operation HEAT COOL DRY FAN Cooling or Dry Defined temperature in temperature setting Heating Determined by outdoor temperature Instructions relating to heating are applicable only to HEAT COOL M...

Страница 9: ...FF time or ON time Set the time while the time indicator is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light...

Страница 10: ... Set time 1 hour 1 C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SL...

Страница 11: ...cle M Adjust the up down left and right air directions with the air direction buttons on the remote controller M Use the air direction buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types o...

Страница 12: ...oner s fan is not operating or when operating at very low speeds M To select up down swing operation ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green...

Страница 13: ...al code is set to A prior to shipment Contact your retailer to change the signal code M The remote controller resets to signal code A when the batteries in the remote controller are replaced If you use a signal code other than signal code A reset the signal code after replacing the batteries If you do not know the air conditioner signal code setting try each of the signal codes until you find the c...

Страница 14: ...fter washing allow the air filters to dry thoroughly in an area protected from sunlight Air filter Filter Reset ECONOMY indicator lamp flashing The special setting M Can be used if set correctly during installation Please consult authorized serviceman when using this function It lights on when it is time to clean the air filters After turning the power on press the MANUAL AUTO button for 2 seconds or ...

Страница 15: ...oor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted M During cooling or dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden cooling of room air by the air emitted from the air conditioner resulting in condensation and misting M During heating operation the outdoor...

Страница 16: ...stop and the defrosting circuit will operate briefly for about 4 to 15 minutes During automatic defrosting operation the OPERATION indicator lamp green will flash Low Ambient Cooling M When the outdoor temperature drops the outdoor unit s fans may switch to low speed Hot Start for heating M The indoor unit prevents cold drafts when heating operation begins The indoor unit fan will not operate or it ...

Страница 17: ...oller to resume operation AUTO Restart In Event of Power Interruption M During use of the heating mode the top of the indoor unit may become warm but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped it is not a malfunction Notices M During use of the heating mode the outdoor unit will occa sionally commence the defrost operation for brief periods D...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: