![Fujitsu Impact 3650 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/fujitsu/impact-3650/impact-3650_maintenance-manual_120326020.webp)
20
CHAPTER 3 TROUBLESHOOTING
This chapter helps pinpoint the causes of problems with the printer.
Section 3.1 is a troubleshooting table. The table shows how to determine what is wrong with the printer and what
to do to correct the problem.
Section 3.2 explains error displays on the control panel that help clarify the cause of a problem.
Section 3.3 explains the self-correction functions of the impact 3650 printer.
For replacement and adjustment after recovery, see Chapter 4.
3.1 Trouble shooting Table
3.1.1 Problems at power-on initialization (part 001/3)
Symptom
Cause
Response
−
The power cord is not
connected to the outlet
or the printer.
Connect the power cord
properly
The power cord is
defective.
Replace the power cord.
The power supply is
defective.
Replace the power
supply.
The control board is
defective.
Replace and initialize
the control board.
The control panel
board is defective.
Replace the control
panel board.
1 The POWER lamp does
not go on.
The power cord is connected
properly.
The cable connected
to the control panel
board is defective.
Check the connection.
Check the cable.
Turn off the power, then wait
for about 10 minutes.
Disconnect the space motor
connector and turn on the
power.
Initialization is not done but
The POWER lamp comes on.
An SP motor fire
check alarm is
detected.
• Replace the SP motor.
• Replace the control
board, then initialize
the EEPROM.
Turn off the power, then wait
for about 10 minutes.
Disconnect the main LF
motor connector and turn on
the power. Initialization is
done.
A main LF motor fire
check alarm is
detected.
• Replace the main
motor.
• Replace the control
board, then initialize
the EEPROM.
2 The POWER lamp
comes on momentarily,
but goes off. Then, turn
the power switch OFF,
and turn on the power
after 10 to 20 seconds.
However, the
POWER lamp does
not go on.
Turn off the power, then wait
for about 10 minutes.
Disconnect the tractor LF
motor connector and turn on
the power. Initialization is
done.
A tractor LF motor
fire check alarm is
detected.
• Replace the tractor LF
motor.
• Replace the control
board, then initialize
the EEPROM.