137
5.3.2.3 Centronics Controller
Figure 5.3.8 is an interface control block diagram.
MB90706
Figure 5.3.8 Interface control block diagram
[Centronics interface control]
The Centronics interface controller uses the Centronics controller built in the MB90706 as shown in Figure 5.3.8
The INPRM and EXPRM signals, which are forcible reset signals from the host, are used as interrupt signals after
noise is removed from them by sampling in the anti-noise interrupt control circuit.
This printer supports nibble mode conforming to IEEE Std 1284-1994.
The following shows the circuits used for two-way Centronics control.
(1) Negotiation mode interrupt signal generator
MB90706
*SLCTIN NEGO
(1284 Active)
*AFXT
(Host Busy)
LS14
LS14
LS14
LS08
IRQ
36Pin
14Pin
Centronics
Driver/
receiver
Host
Centronics
controller
External
interrupt
control unit
DSTB, DATA1:8,
ACK,BUSY,PE
Anti-noise
interrupt
control unit
Interrup
CPU core
Centronics
Interface board
INPRM,EXPRM
Содержание Impact 3650
Страница 112: ...112 ...