12
Instruction manual “1353-EN”
Heat pump, split, single service
Line
Function
Setting range or
display
Setting
increment
B a s i c
setting
Heating time programme, circuit 2
If the installation consists of 2 heating circuits (only with the 2nd circuit kit option)
520
Pre-selection (day / week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
521
1st phase On (start)
00 : 00… - -:- -
10 min
6 : 00
522
1st phase Off (end)
00 : 00… - -:- -
10 min
22 : 00
523
2nd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
524
2nd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
525
3rd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
526
3rd phase Off (end)
00 : 00… - -:- -
10 mn
- -:- -
536
Standard values, Circuit 2
no, yes
no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.
Time programme 4 / DHW
If the installation is fitted with a tank (only with the DWH kit option)
560
Pre-selection (day / week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
561
1st phase On (start)
00 : 00… - -:- -
10 min
00 : 00
562
1st phase Off (end)
00 : 00… - -:- -
10 min
05: 00
563
2nd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
564
2nd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
565
3rd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
566
3rd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
576
Standard values
no, yes
no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.
Time programme 5 / Cooling
If the installation is fitted with the cooling kit (only with the cooling kit option)
600
Pre-selection (day / week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday…
Mon-Sun
601
1st phase On (start)
00 : 00… - -:- -
10 min
6 : 00
602
1st phase Off (end)
00 : 00… - -:- -
10 min
22 : 00
603
2nd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
604
2nd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
605
3rd phase On (start)
00 : 00… - -:- -
10 min
- -:- -
606
3rd phase Off (end)
00 : 00… - -:- -
10 min
- -:- -
616
Standard values
no, yes
no
Yes + OK: The standard values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.