NOTES:
• The air conditioner custom code is set to prior to shipment.
• The remote controller resets to custom code when the batteries on the remote controller are
replaced. If you use a custom code other than code , reset the custom code after replacing the
batteries.
• If you do not know the air conditioner custom code setting, try each of the custom codes ( →
→ → ) until you find the code that operates the air conditioner.
STEP 2: Selecting the function number and setting value
1. Press the TEMP. ( ) ( ) buttons to select the function number.
To switch between the left and right digits, press the 10 °C HEAT
button.
2. Press the POWERFUL button to proceed the setting value. To re-
turn the function number selection, press the POWERFUL button
again.
3. Press the TEMP. ( ) ( ) buttons to select the setting value. To
switch between the left and right digits, press the 10 °C HEAT but-
ton.
4. Press the MODE button, and START/STOP button, in the order
listed to confirm the settings.
5. Press the RESET button to cancel the function setting mode.
6. After completing the function setting, be sure to disconnect the
power supply and then reconnect it.
Function number
Setting value
CAUTION
After disconnecting the power supply, wait 30 seconds or more before reconnecting it. The function
setting will not become active unless the power supply is disconnected and then reconnected.
- 30 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASHG07-14KMCC
WALL MOUNTED
ASHG07-14KMCC
Содержание General AOHG07KMCC
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASHG07KMCC ASHG09KMCC ASHG12KMCC ASHG14KMCC ...
Страница 42: ... 38 13 2 Others 13 Optional parts WALL MOUNTED ASHG07 14KMCC WALL MOUNTED ASHG07 14KMCC ...
Страница 43: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOHG07KMCC AOHG09KMCC AOHG12KMCC AOHG14KMCC ...