11. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
11-1. Function settings by using remote controller
Some function settings can be changed on the remote controller. After confirming the setting proce-
dure and the content of each function setting, select appropriate functions for your installation envi-
ronment.
¢
Setting procedure by using wireless remote controller
The function number and the associated setting value are displayed on the LCD of the remote con-
troller. Follow the instructions written in the local setup procedure supplied with the remote controller,
and select appropriate setting according to the installation environment.
Before connecting the power supply of the indoor unit, reconfirm following items:
• Piping air tight test and vacuuming have been performed firmly.
• There is no wiring mistake.
Then, connect the power supply of the indoor unit.
Entering function setting mode:
While pressing the POWERFUL button and TEMP. ( ) button simultaneously, press the RESET
button to enter the function setting mode.
STEP 1: Setting the remote controller custom code
Use the following steps to select the custom code of the remote controller. (Note that the air condi-
tioner cannot receive a custom code if the air conditioner has not been set for the custom code.)
The custom codes that are set through this process are applicable only to the signal in the function
setting.
For details on how to set the custom codes through the normal process, refer to
ting for wireless remote controller"
1. Press the TEMP. ( ) ( ) buttons to change the custom code be-
tween → → → . Match the code on the display to the air con-
ditioner custom code. (Initially set to .) If the custom code does
not need to be selected, press the 10 °C HEAT button, and pro-
ceed to
STEP 2
.
2. Press the MODE button and check that the indoor unit can receive
signals at the displayed custom code.
3. Press the 10 °C HEAT button to accept the custom code, and pro-
ceed to
STEP 2
.
4. After completing the function setting, be sure to disconnect the
power supply and then reconnect it.
- 29 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASHG07-14KMCC
WALL MOUNTED
ASHG07-14KMCC
Содержание General AOHG07KMCC
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASHG07KMCC ASHG09KMCC ASHG12KMCC ASHG14KMCC ...
Страница 42: ... 38 13 2 Others 13 Optional parts WALL MOUNTED ASHG07 14KMCC WALL MOUNTED ASHG07 14KMCC ...
Страница 43: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOHG07KMCC AOHG09KMCC AOHG12KMCC AOHG14KMCC ...