8. External input and output
With using external input and output functions, this product can be operated inter-connectedly with
an external device.
Connector
Input
Output
Remarks
CNA01
Control input
—
See external input/output
settings for details.
CNB01
—
Operation status output
CNB02
—
Error status output
8-1. External input
With using external input function, some functions on this product can be controlled from an external
device.
• “Operation/Stop” mode can be selected with function setting of indoor unit.
• A twisted pair cable (22AWG) should be used. Maximum length of cable is 150 m.
• The wire connection should be separate from the power cable line.
¢
Control input (Operation/Stop or Forced stop)
The air conditioner can be remotely operated by means of the following on-site work.
Unit operation is started at the following contents by adding the contact input of a commercial on/off
switch to a connector on the external control PCB and turning it on.
Unit operation
Initial setting after power is on
Starting mode other than initial setting
Operation mode
Auto changeover
Mode at previous operation
Set temperature
24 °C
Temperature at previous operation
Airflow mode
AUTO
Mode at previous operation
Air direction (swing)
Standard air direction (swing: off)
Air direction at previous operation
- 20 -
8-1. External input
8. External input and output
WALL MOUNTED
ASHG07-14KMCC
WALL MOUNTED
ASHG07-14KMCC
Содержание General AOHG07KMCC
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASHG07KMCC ASHG09KMCC ASHG12KMCC ASHG14KMCC ...
Страница 42: ... 38 13 2 Others 13 Optional parts WALL MOUNTED ASHG07 14KMCC WALL MOUNTED ASHG07 14KMCC ...
Страница 43: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOHG07KMCC AOHG09KMCC AOHG12KMCC AOHG14KMCC ...