46
Operating Manual
FibreCAT
TXF
Replacing the backup device
Troubleshooting
Ê
Loosen the two screws on each side and remove the guide rails from the
defective backup device.
Ê
Screw the two guide rails on to the new backup device using two screws on
each rail.
V
CAUTION!
Use the screws that are supplied with the backup device. The old
screws may be too long and therefore damage the backup device.
Ê
Before installing a new SCSI backup device:
Set the SCSI ID and set the "Termination Power" jumper to the "Off" position.
Ê
Connect the power supply cable and data cable to the backup device.
Figure 29: Attaching the cable chain
Ê
Insert the backup device into the slot until you can attach the cable chain in
the guide rail.
Ê
Insert the couple part in the guide rail.
Ê
Hold it in position with one finger and push the backup device into the slot
until the couple part is inserted together with the guide rail.
Ê
Now insert the backup device fully into the slot.