FibreCAT TXF
Operating Manual
25
Installation
Installation in the PRIMECENTER Rack or DataCenter Rack
3.5
Installation in the PRIMECENTER Rack or
DataCenter Rack
For installation in the PRIMECENTER Rack, one rack mounting kit with bearing
rails and one rack installation kit with telescopic rails are supplied.
The following parts are required:
–
Support bracket
–
One left and one right bearing rail or telescopic rail (mounted)
–
M5x10 screws with integrated plugwashers
I
–
Or, M5x10 screws with separate plugwashers can also be used. In
this case, two plugwashers each must be fitted beforehand on the
support uprights and the support bracket.
–
General information is provided in the Technical Manual for the
PRIMECENTER and/or DataCenter Rack.
3.5.1
Bearing rail variant
When mounting the left bearing rail in the PRIMECENTER/DataCenter Rack,
the supplied support bracket must first be mounted on the rear left support
upright flush with the bottom edge of the device.
Figure 4: Fitting the support bracket
Ê
Position the support bracket at the corresponding height on the rear left
support upright, (insert lug in corresponding hole) (1).
Ê
Secure the bracket with two screws incl. plug washers (2).
1
2
Содержание FibreCAT TXF
Страница 1: ...FibreCAT TXF Backup Subsystem Operating Manual Edition November ...
Страница 10: ......
Страница 18: ......
Страница 24: ...24 Operating Manual FibreCAT TXF Rack requirements Installation Figure 3 Mechanical requirements ...
Страница 48: ......
Страница 54: ......