Appendix A Syslog Messages
FUJITSU Storage ETERNUS Multipath Driver V2 User’s Guide for Linux
Copyright 2014 FUJITSU LIMITED
P2U3-0031-15ENZ0
133
SCSI%u (%u, %u ,%u): ERROR=0xb: HBA soft error
Cause
The indicated HBA has reported a soft error.
%u are numbers.
Action
Contact a Fujitsu engineer.
SCSI%u (%u, %u ,%u): ERROR=0xf: HBA transport fail fast
Cause
The indicated HBA has reported a transport fail fast.
%u are numbers.
Action
Check the storage system to server connections and respond as necessary.
SCSI%u (%u, %u ,%u): HBA ERROR=0x%x
Cause
The indicated HBA has reported an error.
%u and %x are numbers.
Action
Contact a Fujitsu engineer.
SCSI%u (%u, %u ,%u): MSG ERROR=0x%x
Cause
The indicated HBA has reported an error.
%u and %x are numbers.
Action
Contact a Fujitsu engineer.
SCSI%u (%u, %u ,%u): check condition too long
Cause
The indicated storage system has reported a check condition.
%u are numbers.
Action
Check the storage system and respond as necessary.
SCSI%u (%u, %u ,%u): device busy
Cause
The indicated storage system is in BUSY status.
%u are numbers.
Action
Check the storage system and respond as necessary.
Содержание ETERNUS Multipath Driver V2
Страница 1: ...FUJITSU Storage ETERNUS Multipath Driver V2 User s Guide P2U3 0031 15ENZ0 for Linux ...
Страница 2: ...This page is intentionally left blank ...
Страница 140: ......