Chapter 10 Notes when Using the Multipath Driver
10.5 Frequently Asked Questions
FUJITSU Storage ETERNUS Multipath Driver V2 User’s Guide for Linux
Copyright 2014 FUJITSU LIMITED
P2U3-0031-15ENZ0
114
10.5
Frequently Asked Questions
●
Q1.
Why does the result of the "iompadm info" command display information for storage systems, paths, and
LUs that do not exist?
●
A1.
The result of the "iompadm info" command may display information for fail status storage systems, paths,
and LUs that do not exist when one of the following OSs is used in the conditions described below.
OS:
-
Red Hat Enterprise Linux AS v.4
-
Red Hat Enterprise Linux ES v.4
-
Red Hat Enterprise Linux 5
-
SUSE Linux Enterprise Server 9 (Service Pack 2 or later)
-
SUSE Linux Enterprise Server 10 (Service Pack 1 or later)
Condition:
-
When replacing a storage system
-
When changing the server to storage system connection
-
When changing the server-side LU recognition settings
Execute the "mpdconfig -d" command to remove the unnecessary information.
If unnecessary information remains displayed, the following message may be sent to the syslog at ten-
minute intervals.
("XXXXX" and "YYYYY" are arbitrary numbers)
Timed out waiting for hotplug event XXXXX. Rebasing to YYYYY