Chapter 2 Operating the Library
2.6 Maintaining the Library
FUJITSU Storage ETERNUS LT260 Tape Library User’s Guide -Panel Operation-
Copyright 2016 FUJITSU LIMITED
P3AM-8802-04ENZ0
50
■
To run the element test
Procedure
1
Navigate to the Maintenance > Library Tests > Element to Element Test screen.
2
Select a cartridge from the Source Elements list.
To select from a subset of the cartridges:
a Click Filter On.
b Enter characters into the search box and then click Search.
The Source Elements list is updated to only include cartridges with a barcode label including the
search characters.
3
Select a location from the Destination Elements list.
4
Select the number of cycles.
5
Click Start Test.
End of procedure
2.6.1.4
Position Test
The position test moves the robotic assembly vertically between two elements. The number of movements
can be specified.