8.2
Server Connection Setup
Set up the server as required to connect to the ETERNUS DX.
The IP address to connect to the iSCSI network must be set on the server before the ETERNUS DX is connected.
After the server connection setup is completed, confirm that the volumes in the ETERNUS DX can be recog-
nized by the server.
Figure 8.1 Connection Configuration with Servers
iSCSI multipath
connection
Server (host)
ETERNUS DX
LAN card#0
A
LAN card#1
B
CA#0 Port#0
C
CM#0
CA#0 Port#0
D
CM#1
8.2.1
iSCSI Initiator Parameter Settings (Connection Information Settings)
Use the iSCSI Software Initiator to set the iSCSI initiator parameters.
After performing the settings, check the connection to the ETERNUS DX.
Turn on the ETERNUS DX while its iSCSI port is connected to the LAN port for iSCSI connection on the server
with the host interface cable. After confirming that the ETERNUS DX is in READY status, turn on the server.
1
On the [iSCSI Initiator Properties] screen, click the [Discovery] tab.
Chapter 8 SAN Connection Settings
8.2 Server Connection Setup
115
FUJITSU Storage ETERNUS DX60 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-9002-01ENZ0