Chapter 5
Power Control Setup
Perform power control settings as required.
Power control settings must be performed if the Auto Power function (AC automatic linkage mode) is ena-
bled, the Power Resume function (automatic power recovery mode) is enabled, the power synchronized unit
is connected, or the Wake On LAN function is used.
For details on the settings, refer to "Configuration Guide (Web GUI)".
5.1
Setup of the Auto Power Function and/or the Power Resume
Function
To automatically turn on the ETERNUS DX when AC power is supplied or when power is restored after a power
failure, use ETERNUS Web GUI to enable the Auto Power function and/or the Power Resume function.
•
Auto Power function (AC automatic linkage mode)
When the Auto Power function is enabled, the ETERNUS DX is automatically turned on when AC power is
supplied.
The Auto Power function is disabled for the factory default setting.
•
Power Resume function (automatic power recovery mode)
When the Power Resume function is enabled, the ETERNUS DX is automatically turned on when the power
supply is restored after a power failure.
The Power Resume function is disabled for the factory default setting.
shows how the ETERNUS DX operates when the Auto Power function and the Power Resume func-
tion are enabled or disabled.
Table 5.1 ETERNUS DX Operation According to the Settings of the Auto Power Function and the Power Resume
Function
Settings for the power control functions
How the ETERNUS DX operates
Auto Power function is disabled
Power Resume function is disabled
The ETERNUS DX is not automatically turned on even when AC power is
supplied or when power is restored after a power failure.
Auto Power function is enabled
Power Resume function is disabled
The ETERNUS DX is automatically turned on when AC power is supplied.
The ETERNUS DX is not turned on even when power is restored after a pow-
er failure.
Auto Power function is disabled
Power Resume function is enabled
The ETERNUS DX is not turned on automatically even when AC power is
supplied.
The ETERNUS DX is automatically turned on when power is restored after a
power failure.
Auto Power function is enabled
Power Resume function is enabled
The ETERNUS DX is automatically turned on when AC power is supplied and
when power is restored after a power failure.
The procedure to enable the Auto Power function and/or the Power Resume function is described below.