background image

FUJITSU Storage
ETERNUS DX500 S3/DX600 S3
Disk storage system
 
Configuration Guide (Basic)

P3AM-7732-05ENZ0

Содержание Eternus DX500 S3

Страница 1: ...FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic P3AM 7732 05ENZ0 ...

Страница 2: ...This page is intentionally left blank ...

Страница 3: ...ed to monitor the ETERNUS DX Chapter 5 Power Control Setup page 82 This chapter describes the settings required for power control of the ETERNUS DX Chapter 6 SAN Connection Settings page 86 This chapter describes the settings required to use the ETERNUS DX with a SAN connection Chapter 7 Advanced Copy Settings page 118 This chapter describes the settings required to operate Advanced Copy Chapter 8...

Страница 4: ...shot s reprinted with permission from Microsoft Corporation Naming Conventions Product Names The following abbreviations are used for Microsoft Windows Server Product name Abbreviation Microsoft Windows Server 2003 Datacenter Edition Windows Server 2003 Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2008 Datacenter Microsoft...

Страница 5: ...tes supplementary and reference information Abbreviations Used in This Manual ETERNUS DX500 S3 refers to the FUJITSU Storage ETERNUS DX500 S3 Disk storage system and ETERNUS DX600 S3 refers to the FUJITSU Storage ETERNUS DX600 S3 Disk storage system ETERNUS DX refers to the ETERNUS DX500 S3 and ETERNUS DX600 S3 Disk storage systems CA refers to a host interface module that is used in an ETERNUS DX...

Страница 6: ...PORTANT information for the user to note when using the ETER NUS DX The following symbols are used to indicate the type of warnings or cautions being described Electric Shock The triangle emphasizes the urgency of the WARNING and CAUTION contents Inside the triangle and above it are details concerning the symbol e g Electrical Shock No Disassembly The barred Do Not circle warns against certain act...

Страница 7: ...dicator Warning details To avoid damaging the ETERNUS DX pay attention to the following points when cleaning the ETERNUS DX Make sure to disconnect the power when cleaning Be careful that no liquid seeps into the ETERNUS DX when using cleaners etc Do not use alcohol or other solvents to clean the ETERNUS DX Warning layout ribbon Example warning CAUTION Do Preface 7 FUJITSU Storage ETERNUS DX500 S3...

Страница 8: ...abels are attached to the rear Device ID label The model name and the serial number are listed Manufacturer s label The model name and the serial number are listed This label can be viewed by pulling out the label plate when the controller enclosure is installed in a rack This label is attached on the label plate which is located on the left rear side of the controller enclosure This label can be ...

Страница 9: ...Manufacturer s label The model name and the serial number are listed Device ID label The model name and the serial number are listed Preface 9 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 10: ...Enclosures 2 5 type drive enclosure 3 5 type drive enclosure Preface 10 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 11: ... High density drive enclosure Preface 11 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 12: ... such as the model name and serial number is indicated Power distribution unit AC200 240V 2U Manufacturer s label Information such as the model name and serial number is indicated Preface 12 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 13: ... 28 2 3 Preparation and Setup for the Administration Terminal 31 2 4 LAN Connection Preparation for Operation Management 31 2 4 1 LAN Related Specifications 31 Chapter 3 General Settings 33 3 1 Powering On 36 3 1 1 Switching On and Off the Main Line Switch on the Power Distribution Unit 36 3 1 2 Switching On and Off the PSU Switch on the Power Supply Unit 37 3 1 3 Powering On 38 3 2 ETERNUS Web GU...

Страница 14: ...2 Send Test Mail 80 Chapter 5 Power Control Setup 82 5 1 Setup of the Auto Power Function and or the Power Resume Function 82 5 2 Connection Setup for Power Synchronized Unit 83 5 3 Wake On LAN Settings 84 Chapter 6 SAN Connection Settings 86 6 1 Connection Settings for the ETERNUS DX 86 6 1 1 Host Response Settings 86 6 1 2 Host Affinity Settings 87 6 1 3 CA Reset Group Settings 95 6 2 Server Con...

Страница 15: ... 1 Continuous Business 134 9 1 1 Remote Copy Operations for the Storage System Copies Between ETERNUS DX storage systems 134 9 1 2 Automatic Switching Operation of the Storage Systems Storage Cluster 136 9 2 Storage Optimization 138 9 2 1 Automated Storage Tiering 138 9 2 2 Performance Tuning 139 9 3 Green 142 9 4 Virtualization Platform 144 9 4 1 Oracle VM Linkage 144 9 4 2 VMware Linkage 145 9 4...

Страница 16: ...r Distribution Unit 36 Figure 3 4 ON Position Marked of the Main Line Switches on a 2U Power Distribution Unit 36 Figure 3 5 ON Position Marked of the PSU Switch on a Power Supply Unit 37 Figure 3 6 RAID Group Creation 50 Figure 3 7 RAID Group Information After Creation 52 Figure 3 8 Operation Volume Creation 53 Figure 3 9 Generation Management Volume SDV Creation 55 Figure 3 10 Copy Data Destinat...

Страница 17: ...p Creation 50 Table 3 2 Operation Volume Creation 53 Table 5 1 ETERNUS DX Operation According to the Settings of the Auto Power Function and the Power Resume Function 82 17 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 18: ...llers and the power supply units are installed in the rear 1 1 1 Front This section provides the names of the components in the front of a controller enclosure Figure 1 1 Front View of a Controller Enclosure 1 2 1 Operation panel 2 Front cover 18 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 19: ...ntroller 0 CM 0 2 Controller 1 CM 1 3 Host interface CA 0 4 Host interface CA 1 5 LAN FST port 6 LAN RMT port 7 LAN MNT port 8 Drive interface OUT port 9 PWC port 10 Power supply unit CPSU 0 11 Power supply unit CPSU 1 Chapter 1 Component Names 1 1 Controller Enclosures 19 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 77...

Страница 20: ...rface CA 1 5 Host interface CA 2 6 Host interface CA 3 7 LAN FST port 8 LAN RMT port 9 LAN MNT port 10 Drive interface OUT port 11 PWC port 12 Power supply unit CPSU 0 13 Power supply unit CPSU 1 Chapter 1 Component Names 1 1 Controller Enclosures 20 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 21: ...ovides the names of the components in the front of a drive enclosure 2 5 Type Figure 1 4 Front View of a 2 5 Type Drive Enclosure 1 3 3 2 1 Operation panel 2 2 5 drive 3 Flange cover 3 5 Type Figure 1 5 Front View of a 3 5 Type Drive Enclosure 1 3 3 2 1 Operation panel 2 3 5 drive 3 Flange cover Chapter 1 Component Names 1 2 Drive Enclosure 21 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage...

Страница 22: ...e enclosure 2 5 Type 3 5 Type Figure 1 7 Rear View of a 2 5 Type 3 5 Type Drive Enclosure 3 4 1 2 5 6 3 4 1 I O module IOM 0 2 I O module IOM 1 3 Drive interface IN port 4 Drive interface OUT port 5 Power supply unit PSU 0 6 Power supply unit PSU 1 Chapter 1 Component Names 1 2 Drive Enclosure 22 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014...

Страница 23: ...PSU 3 9 Fan expander module FEM 0 10 Fan expander module FEM 1 1 3 Power Distribution Units for Regions Other than EMEA I There are two sizes for power distribution units 1U and 2U 1 3 1 Power Distribution Units 1U The 1U power distribution unit has four outlets and two inlets Chapter 1 Component Names 1 3 Power Distribution Units for Regions Other than EMEA I 23 FUJITSU Storage ETERNUS DX500 S3 D...

Страница 24: ...0V 2U 12 Outlets There are 12 outlets Figure 1 10 Power Distribution Unit AC200 240V 2U 12 Outlets 2 1 1 Main line switch 2 Outlet OUTPUT 1 3 2 2 Power Distribution Unit AC200 240V 2U 16 Outlets There are 16 outlets Figure 1 11 Power Distribution Unit AC200 240V 2U 16 Outlets 2 1 1 Main line switch 2 Outlet OUTPUT Chapter 1 Component Names 1 3 Power Distribution Units for Regions Other than EMEA I...

Страница 25: ...mail notification syslog notification and remote support via LAN Generation management of data by acquisition of backup based on the day of the week with generation copy using SnapOPC Configuration Diagram The following diagram shows a system configuration example Figure 2 1 System Configuration Example ETERNUS DX Remote support center iSCSI SAN Multipath LAN for Operation Management Server SNMP m...

Страница 26: ...nvironment for the HBA that is to be used by referring to the HBA manual This section uses an iSCSI connection as an example to explain the required preparation for server connec tion 2 2 1 Driver Preparation Prepare required drivers and utilities LAN card driver for iSCSI LAN driver Supported version of iSCSI Software Initiator This is already installed in a server that runs Windows Server 2008 o...

Страница 27: ...nto the server then from Windows Explorer double click on setup msi in the Eng lish folder of the CD ROM A screen to confirm the start of installation appears 2 Click the Next button A screen to specify the installation directory of the ETERNUS Multipath Driver and which user installs the driver appears 3 To change the installation directory click the Browse button and select the installation dire...

Страница 28: ...ose button A screen to confirm whether to restart the computer appears 6 Restart the server 2 2 3 iSCSI Initiator Parameter Settings The following procedure explains how to set the iSCSI initiator parameters This section shows how to set an iSCSI initiator name 1 In Administrative Tools click iSCSI Initiator 2 For the first startup the dialog box that is shown below appears If there is no problem ...

Страница 29: ...ick the Configuration tab Chapter 2 Checking the Configuration Environment 2 2 Server Connection Preparation 29 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 30: ...d click the OK button To use the default initiator name also click the Change button This allows you to continue to use this initiator name even after changing the server name Chapter 2 Checking the Configuration Environment 2 2 Server Connection Preparation 30 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 31: ... the required settings refer to Configuration Guide Web GUI 2 4 LAN Connection Preparation for Operation Management 2 4 1 LAN Related Specifications Network Communication Protocols The usable LAN ports and functions are different depending on the usage and protocol The following table shows how the LAN ports may be used by usage and protocol Table 2 2 LAN Port Availability Usage Protocol tcp udp P...

Страница 32: ...Possible Partially possible Not possible 1 Only the following functions are available Checking the ETERNUS DX status Switching the Master CM 2 May use either the MNT port or RMT port 3 Modifiable For details on the port numbers for the ETERNUS SF Software refer to the manual of each Storage Foundation Software ETERNUS SF Communication Modes The default LAN operation mode is Auto Negotiation which ...

Страница 33: ...ares in the ETERNUS DX Monitoring Settings Perform the settings to enable constant monitoring of the storage system status For details on these set tings refer to Chapter 4 Monitoring Settings page 62 Power Control Setup Perform the storage system power control settings For details on these settings refer to Chapter 5 Power Control Setup page 82 SAN Connection Settings Perform the settings for SAN...

Страница 34: ...ssigned drive Figure 3 1 Example of Differential Backup Settings with SnapOPC Operation data F Sunday data Saturday data Friday data Thursday data Wednesday data Tuesday data Monday data G 1st generation H 2nd generation I 3rd generation J 4th generation K 5th generation L 6th generation M 7th generation Server ETERNUS DX Generation management of data that is acquired daily SnapOPC By mounting the...

Страница 35: ...me 2 1TB 500GB Generation management volume Operation volume Copy data destination volume sdv0 sdpv main sdv1 sdv2 sdv3 sdv4 sdv5 sdv6 1 SDV is used as the copy destination for SnapOPC and stores generation data 2 SDPV is the expansion area of the SDV and is used to configure the Snap Data Pool SDP area Chapter 3 General Settings 35 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Con...

Страница 36: ...he main line switches are in the ON position For 1U Figure 3 3 ON Position Marked of the Main Line Switches on a 1U Power Distribution Unit Main line switch For 2U Figure 3 4 ON Position Marked of the Main Line Switches on a 2U Power Distribution Unit Main line switch Chapter 3 General Settings 3 1 Powering On 36 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Bas...

Страница 37: ...on Figure 3 5 ON Position Marked of the PSU Switch on a Power Supply Unit Power supply unit PSU 0 Power supply unit PSU 1 AC power is supplied to an enclosure For the drive enclosure the POWER LED on the power supply unit emits green lights and the fan revolves at high speed for 30 seconds POWER LED Drive enclosure Power supply unit PSU 0 Power supply unit PSU 1 Chapter 3 General Settings 3 1 Powe...

Страница 38: ...e in a READY state This should be taken into consideration for scheduled opera tions Before turning the server on check that the ETERNUS DX and the network devices that connect the ETERNUS DX and the server are all in READY status If the server is turned on while any of these devices are not in READY status the server may not be able to recognize the ETERNUS DX To turn on the ETERNUS DX by linking...

Страница 39: ...d terminal If the settings of the Web browser are incorrect ETERNUS Web GUI may not be connected For details on these settings refer to Configuration Guide Web GUI 1 Open the Web browser on the terminal 2 Enter the IP address that is set in the ETERNUS DX in the address bar of the Web browser The login screen for ETERNUS Web GUI appears 3 To change the language click the Option button and select E...

Страница 40: ...g settings according to the wizard screen Set Storage System Name Change User Password Set Thin Provisioning Register SED Authentication Key Setup Network Environment The procedure for initial setup is shown below For details on the settings refer to Configuration Guide Web GUI Chapter 3 General Settings 3 3 Storage Management Initial Setup 1 40 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk stora...

Страница 41: ...used for network management by SNMP The name of the ETER NUS DX is displayed in the login and operation screens of ETERNUS Web GUI 1 Set the required items and click the Next button A confirmation screen appears Chapter 3 General Settings 3 3 Storage Management Initial Setup 1 41 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED ...

Страница 42: ... screen appears 2 Click the OK button The password is changed and the change completion screen appears 3 Click the Done button The Set Thin Provisioning screen appears 4 Thin Provisioning setup Enable or disable the Thin Provisioning function and set the maximum pool capacity Chapter 3 General Settings 3 3 Storage Management Initial Setup 1 42 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage...

Страница 43: ... is set and the change completion screen appears 3 Click the Done button The Register Advanced Copy License screen appears Chapter 3 General Settings 3 3 Storage Management Initial Setup 1 43 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 44: ... SEDs are installed in the ETERNUS DX register the SED authentication key 1 A message to confirm whether to register the SED authentication key is displayed Click the Next button Chapter 3 General Settings 3 3 Storage Management Initial Setup 1 44 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 45: ...default some functions are not available Make sure to set up the network environment Configure the IP addresses of the MNT port the RMT port and the FST port with IP addresses in different subnetworks When specifying the IP address of the Slave CM specify an IP address that is in the same subnet but is different from the IP address of the Master CM Either or both an IPv4 address and an IPv6 addres...

Страница 46: ...reen appears 2 Click the OK button The network environment setting is applied and the setting completion screen appears 3 Click the Finish button The Logout screen appears 8 Logout 1 Click the Close button Chapter 3 General Settings 3 3 Storage Management Initial Setup 1 46 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7...

Страница 47: ...GUI If both Telnet connection and SSH connection are disabled the device is inaccessible via ETERNUS CLI If the network environment for the MNT port is not set up some functions will be unusable Make sure to set up the network environment 1 Click the System tab on the navigation of the ETERNUS Web GUI screen 2 In Category click Network The Network screen appears 3 Select the port to be set In Acti...

Страница 48: ...connections from things such as monitoring software or for using the re mote support function to download firmware between storage systems SSH encrypts and sends receives data SNMP This service is enabled when an ETERNUS DX is connected via the SNMP manager ETERNUS DX Discovery Change the setting to Disable 5 Click the Set button 6 In the confirmation screen click the OK button The firewall settin...

Страница 49: ...case of creating the following volumes as an exam ple Operation volume Create an operation volume Standard in RAID5 4 1 RAID group Backup volume Create a generation management volume SDV and copy data destination volume SDPV in RAID5 2 1 RAID group Chapter 3 General Settings 3 5 RAID Configuration Settings 49 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic C...

Страница 50: ...RG1 Manual RAID5 2TB Nearline SAS disk 3 Do Not Do not uninstall the drives that are installed by default or move them to any other slot Contact your sales representative or maintenance engineer if drives that are instal led by default need to be uninstalled or moved to another slot The procedure to register a RAID group is as follows 1 On the navigation of the ETERNUS Web GUI screen click the RAI...

Страница 51: ...d and the registration completion screen appears 6 Click the Done button The screen display returns to the RAID Group screen 7 After creating an operation RAID group repeat Step 1 and later steps to create a backup RAID group The following screen shows the settings that are displayed when creating a RAID group with the RAID group name RG1 and the RAID level RAID5 2 1 Chapter 3 General Settings 3 5...

Страница 52: ...ter the RAID group is created Figure 3 7 RAID Group Information After Creation Chapter 3 General Settings 3 5 RAID Configuration Settings 52 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 53: ...Generation management volume sdv0 6 1TB 1 Snap Data Volume Copy data destination volume sdpv 500GB Snap Data Pool Volume 1 Though the copy source capacity is specified during creation the capacity allocated to sdv is approxi mately 0 1 of the copy source capacity When creation is finished the volume is automatically formatted After volume creation Standard and SDV become accessible from the host w...

Страница 54: ...turns to the Volume screen 6 Then create SDV and SDPV in the backup RAID group RG1 For the creation procedure refer to 3 5 3 Generation Management Volume SDV Creation page 55 and 3 5 4 Copy Data Destination Volume SDPV Creation page 56 Chapter 3 General Settings 3 5 RAID Configuration Settings 54 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014...

Страница 55: ...navigation of the ETERNUS Web GUI screen The Volume screen appears 2 In Action click Create The Create Volume screen appears 3 Set the required items in the Create Volume screen and click the Create button Name sdv Type Snap Data Volume Capacity of source volume 1TB 1 RAID Group TPP Selection Manual Manual Setting RG1 Number of Volumes 7 2 1 Enter the capacity of the copy source volume during crea...

Страница 56: ...kup RAID group Create a volume as an expansion area of SDV in the backup RAID group RG1 created in 3 5 1 RAID Group Creation page 50 Figure 3 10 Copy Data Destination Volume SDPV Creation Copy data destination volume sdpv Snap Data Pool Volume 500GB Backup RAID group RG1 RAID5 2 1 2TB 2TB 2TB Chapter 3 General Settings 3 5 RAID Configuration Settings 56 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Di...

Страница 57: ...e button Name sdpv Capacity 500GB Type Snap Data Pool Volume RAID Group TPP Selection Manual Manual Setting RG1 A confirmation screen appears 4 Click the OK button The volume is created and the registration completion screen appears 5 Click the Done button The screen display returns to the Volume screen Chapter 3 General Settings 3 5 RAID Configuration Settings 57 FUJITSU Storage ETERNUS DX500 S3 ...

Страница 58: ...ilable Global Hot Spare This is available for any RAID group Dedicated Hot Spare This is only available to the specified RAID group one RAID group For a RAID group that contains important data assign Dedicated Hot Spare in order to preferentially use the hot spare Chapter 3 General Settings 3 5 RAID Configuration Settings 58 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configurati...

Страница 59: ...tab on the navigation of the ETERNUS Web GUI screen On the Component screen click Drives in Category The Drives screen appears 2 Select the drive that is to be registered as the Global Hot Spare and click Assign Global HS in Action A confirmation screen appears 3 Click the OK button The Global Hot Spare is registered and the registration completion screen appears Chapter 3 General Settings 3 5 RAI...

Страница 60: ...GUI screen On the Component screen click Drives in Category The Drives screen appears 2 Select the drive that is to be registered as the Dedicated Hot Spare and click Assign Dedicated HS in Action The Assign Dedicated Hot Spare screen appears Chapter 3 General Settings 3 5 RAID Configuration Settings 60 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyrig...

Страница 61: ... button The Dedicated Hot Spare is registered and the registration completion screen appears 5 Click the Done button The screen display returns to the Drives screen Chapter 3 General Settings 3 5 RAID Configuration Settings 61 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 62: ...plained below 1 On the navigation of the ETERNUS Web GUI screen click System The System screen appears 2 In Category click Event Dump The Event Dump screen appears 3 In Action click Setup Event Notification The Setting based on Severity tab screen of the Setup Event Notification screen appears 4 In the Setting based on Severity tab screen select the required items 5 On the screens that are display...

Страница 63: ...refully read this manual and the manuals for the monitoring software SNMP Manager that is to be used before monitoring the ETERNUS DX ETERNUS DX Settings The SNMP Trap test setting is explained below 1 Set up the network environment for the ETERNUS DX When the ETERNUS DX and the monitoring server are in different subnet environments set the Gate way IP address and the Allowable IP address IP addre...

Страница 64: ...click Setup SNMP Interface The Setup SNMP Agent Basic Interface screen appears 4 Select Enable for SNMP Function set the required items and click the Set button Select the LAN port that was set up in Step 1 for LAN Port used for SNMP A confirmation screen appears Chapter 4 Monitoring Settings 4 2 Various Notification Settings 64 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configu...

Страница 65: ... click the Add button The Manager screen appears 3 Enter the IP address of SNMP Manager monitoring server and click the OK button The screen display returns to the manager list of the Setup SNMP Manager screen 4 Check the SNMP Manager that was added in Step 3 is displayed in the manager list and click the Set button A confirmation screen appears 5 Click the OK button The SNMP Manager settings are ...

Страница 66: ...click the Add button 3 Enter the community name set the required items and click the OK button The screen display returns to the community list of the Setup SNMP Agent Community screen 4 Check the community name that was set in Step 3 is added in the community list and click the Set button A confirmation screen appears 5 Click the OK button The SNMP community settings are applied 6 Check the setti...

Страница 67: ...The SNMP user settings are applied 6 Check the setting completion message and click the Done button The screen display returns to the Network screen 5 Trap setup Set up the destination for sending the SNMP Trap This step is not required when ETERNUS SF Storage Cruiser is used to monitor the ETERNUS DX 1 In Action click Setup SNMP Trap The Setup SNMP Agent Trap screen appears 2 In the trap list of ...

Страница 68: ...the OK button The SNMP Trap settings are applied 6 Check the setting completion message and click the Done button The screen display returns to the Network screen 6 Download the MIB file Download the MIB file that is registered in the ETERNUS DX 1 In Action click Download MIB File The Download MIB File screen appears Chapter 4 Monitoring Settings 4 2 Various Notification Settings 68 FUJITSU Storag...

Страница 69: ...rView A confirmation screen appears 3 Click the OK button A dialog box to download the file appears 4 Click the Save button The MIB file is saved 5 Check the setting completion message and click the Done button The screen display returns to the Network screen Chapter 4 Monitoring Settings 4 2 Various Notification Settings 69 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configurati...

Страница 70: ...ick System The System screen appears 2 In Category click Network The Network screen appears 3 In Action click Setup E Mail Notification The Notification E Mail tab screen of the Setup E Mail Notification screen appears 4 In the Notification E Mail tab screen set the required items Select Yes for Notification E Mail Enter the destination e mail address or addresses for the Destination E Mail Addres...

Страница 71: ...t need to be changed from the default value for normal operation 9 Click the Set button to apply the specified settings A confirmation screen appears 10 Click the OK button The e mail notification settings are applied Chapter 4 Monitoring Settings 4 2 Various Notification Settings 71 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMI...

Страница 72: ...e Syslog server The Syslog setting is explained below 1 On the navigation of the ETERNUS Web GUI screen click System The System screen appears 2 In Category click Network The Network screen appears 3 In Action click Setup Syslog The Setup Syslog screen appears 4 In the Setup Syslog screen set the required items Select on RFC3164 or on RFC5424 for Send Log To send messages in RFC5424 format to a ta...

Страница 73: ...prompt detection and resolution of trouble There are two types for performing remote support function by using AIS Connect function and by using REMCS Note that AIS Connect and REMCS are not available in some regions Contact the Support Department for details AIS Connect and REMCS cannot be used at the same time AIS Connect function can only be used when REMCS is not specified or is stopped When R...

Страница 74: ...appears 2 In Category click AIS Connect in Remote Support The Remote Support screen appears 3 Perform the environment settings for the AIS Connect function 1 In Action click Setup AIS Connect Environment The Setup AIS Connect Environment screen appears 2 Select Enable for AIS Connect and then Country code Country name for Country of Installa tion Country Code Country Name Perform the other additio...

Страница 75: ...in the Send AIS Connect Test Event Result screen 3 Click the Done button The screen display returns to the remote support screen 4 3 2 Remote Support by REMCS Setup When using the remote support function by REMCS perform the environment settings for connecting to the remote support center and register the customer information to send to the remote support center If the AIS Connect function is bein...

Страница 76: ...n The screen display returns to the remote support screen The specified information is sent to the remote support center and the connection of the ETERNUS DX and the remote support center is checked The connection check result is sent to the e mail address that is set in Result notification information Chapter 4 Monitoring Settings 4 3 Remote Support Setup 76 FUJITSU Storage ETERNUS DX500 S3 DX600...

Страница 77: ...pears 2 In Category click Audit Log The Audit Log screen appears 3 If Disable is specified for Audit Log select Enable 1 Click Enable Audit Log in Action A confirmation screen appears 2 Click the OK button Enabling of the audit log starts 3 Check the setting completion message and click the Done button The screen display returns to the Audit Log screen 4 Specify the Syslog server to which the audi...

Страница 78: ...nager Settings Install and set up the monitoring software on the server side Refer to the manual for the monitoring software to install and set the monitoring software Register the file that was downloaded in Download the MIB file Step 6 in 4 2 1 SNMP Trap Setup page 63 as the MIB definition file for the monitoring software Chapter 4 Monitoring Settings 4 5 Monitoring Server SNMP Manager Settings ...

Страница 79: ... screen click System The System screen appears 2 In Category click Network The Network screen appears 3 In Action click Send SNMP Trap The Send SNMP Trap Test screen appears 4 In the Send SNMP Trap Test screen click the Send button A confirmation screen appears 5 Click the OK button The test transmission of the SNMP Trap is performed 6 Check the test transmission completion message and click the D...

Страница 80: ...ing the ping command Is the monitoring software set correctly to monitor the ETERNUS DX Are the SNMP environment settings and the transmission destination for the SNMP Trap set correctly on the ETERNUS DX 4 6 2 Send Test Mail Perform the email transmission test to check that the email can be sent from the ETERNUS DX to the speci fied email address The procedure to send test mail is as follows 1 On...

Страница 81: ... that are set For details on the event code and message of the test mail refer to Message List Chapter 4 Monitoring Settings 4 6 Transmission Test Execution 81 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 82: ...hows how the ETERNUS DX operates when the Auto Power function and the Power Resume func tion are enabled or disabled Table 5 1 ETERNUS DX Operation According to the Settings of the Auto Power Function and the Power Resume Function Settings for the power control functions How the ETERNUS DX operates Auto Power function is disabled Power Resume function is disabled The ETERNUS DX is not automaticall...

Страница 83: ...to Power function and or the Power Resume function setting is applied 7 Check the setting completion message and click the Done button The screen display returns to the System Settings screen 5 2 Connection Setup for Power Synchronized Unit Refer to Configuration Guide Power Synchronized Unit for the required settings to use power control by connecting power synchronized units to an ETERNUS DX Cha...

Страница 84: ...en select Enable for Wake on LAN For operations with cluster connections set the IP address of the Slave CM for the Slave IP Address of the MNT port To control power supply with servers in a network to which the ETERNUS DX does not belong set Gateway and specify the server IP address or the network address in Allowable IP Address 5 Click the Set button A confirmation screen appears 6 Click the OK ...

Страница 85: ... button The screen display returns to the System Settings screen Chapter 5 Power Control Setup 5 3 Wake On LAN Settings 85 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 86: ...n the OS type and operating environment the settings are added when the host response is customized Make sure to perform the appropriate host response settings before performing host group registration If the appropriate host response settings are not set the volumes may not be recognized or the expected performance may not be achieved For details on the host response settings refer to Configurati...

Страница 87: ... the volumes This section provides an example for setting host affinity by associating a host group a CA port group and a LUN group when an iSCSI interface is used for connection Set host affinity in the following order Host group addition Port parameter settings CA port group creation LUN group addition Host affinity creation For the settings for connection using other interfaces refer to Configu...

Страница 88: ...3 Specify a host group name to be created and select a host response to be assigned to the host group 4 Register an iSCSI host in a host group and click the Add button The following screen shot shows registration of a host by clicking the Now Connected tab A confirmation screen appears 5 Click the OK button The iSCSI host group is added and the registration completion screen appears 6 Click the Do...

Страница 89: ...ame can be managed more easily if the port name is added to the end of the default When multiple target ports are selected the parameters must be set for multiple ports Select the port to be set from the pull down menu The following items are set as shown in this example Port CM 0 CA 0 Port 0 IP Version Select an IP address type IPv4 is used in this example IP Address Specify an available IP addre...

Страница 90: ... parameter is set and the setting completion screen appears 5 Click the Done button The screen display returns to the iSCSI Port screen Chapter 6 SAN Connection Settings 6 1 Connection Settings for the ETERNUS DX 90 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 91: ...up The Create iSCSI Port Group screen appears 3 In the Create iSCSI Port Group screen enter the name of the CA port group that is to be created select the checkbox for the ports that are to be registered in the CA port group and click the Create button A confirmation screen appears 4 Click the OK button The CA port group is created and the setting completion screen appears 5 Click the Done button ...

Страница 92: ...N Group screen appears 2 In Action click Add LUN Group The Add LUN Group screen appears 3 Enter the LUN group name in LUN Group Setting Click the Add button in Define LUN Group The Add LUN screen appears 4 Enter the number for the first LUN and number of LUNs to allocate to the LUN group in LUN Setting select the number for the first volume to be allocated and click the OK button Chapter 6 SAN Con...

Страница 93: ...ize a LUN group The procedure to create a host affinity is as follows 1 Click the Connectivity tab on the navigation of the ETERNUS Web GUI screen On the Connectivity screen click Create Host Affinity in Action The Create Host Affinity screen appears 2 Select Host Group CA Port Group in Target Connection 3 Select the Host Group the CA Port Group and the LUN Group that are to be associated 1 Click ...

Страница 94: ...Port Group 5 Click the Browse button in LUN Group A screen to select the LUN group appears 6 Select the LUN group that is to be associated and click the OK button The name of the selected LUN group is displayed in LUN Group 4 Check the path between the host and the host interface port on the ETERNUS DX in Host CA Port Connection and click the Create button A confirmation screen appears 5 Click the...

Страница 95: ...figuration Guide Server Connection for each OS 1 Click the Connectivity tab on the navigation of the ETERNUS Web GUI screen On the Connectivity screen click CA Reset Group in Category 2 Select the CA reset group to be set In Action click Set Reset Group All the ports are configured in one reset group in the initial setting 3 Set the CA reset group member ports and click the Modify button 4 In the ...

Страница 96: ... iSCSI Initiator Parameter Settings Connection Information Settings Use the iSCSI Software Initiator to set the iSCSI initiator parameters After performing the settings check the connection to the ETERNUS DX Turn on the ETERNUS DX while its iSCSI port is connected to the LAN port for iSCSI connection on the server with the host interface cable After confirming that the ETERNUS DX is in READY statu...

Страница 97: ...reen click the General tab 6 Specify the following items under Connect using Local adapter Microsoft iSCSI Initiator Initiator IP IP address of the server A in Figure 6 1 When setting access restrictions the settings related to CHAP authentication is required For details on CHAP authentication refer to Configuration Guide Server Connection Chapter 6 SAN Connection Settings 6 2 Server Connection Se...

Страница 98: ...on The screen display returns to the Discover Target Portal screen 8 Click the OK button Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 98 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 99: ...d settings are correctly reflected to The system will look for Targets on follow ing portals Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 99 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 100: ...e iSCSI Initiator Properties screen click the Targets tab Confirm whether the specified contents in The system will look for Targets on following portals have been applied correctly before checking connection Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 100 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7...

Страница 101: ...target Connect To Target appears 14 Confirm the controller number at the end of the target name and click the Advanced button 15 On the Advanced Settings screen specify the following items under Connect using and click the OK button Local adapter Microsoft iSCSI Initiator Initiator IP IP address of the server A in Figure 6 1 Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 101 FUJITSU...

Страница 102: ...s connection to the list of Favorite Targets checkbox is selected and click the OK button Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 102 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 103: ... for the other target Initiator IP IP address of the server B in Figure 6 1 Target portal IP IP address of the ETERNUS DX D in Figure 6 1 Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 103 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 104: ... changed to Connected and click the OK button Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 104 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 105: ...the Windows Device Manager 1 Open Device Manager and expand Disk drives 2 Confirm that the same number of FUJITSU items are displayed as the number of LUNs that are set If the example is used eight FUJITSU items are displayed Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 105 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJIT...

Страница 106: ... CA numbers of the ETERNUS DX are displayed on ETERNUS Multipath Driver as shown below CM 0 CA 0 Port 0 g CAID 00 CM 1 CA 0 Port 0 g CAID 02 CM 0 CA 0 Port 1 g CAID 01 CM 1 CA 0 Port 1 g CAID 03 CM 0 CA 1 Port 0 g CAID 20 CM 1 CA 1 Port 0 g CAID 22 CM 0 CA 1 Port 1 g CAID 21 CM 1 CA 1 Port 1 g CAID 23 CM 0 CA 2 Port 0 g CAID 40 CM 1 CA 2 Port 0 g CAID 42 CM 0 CA 2 Port 1 g CAID 41 CM 1 CA 2 Port 1...

Страница 107: ...eration volume Standard perform Operation Disk Settings page 111 in 6 2 3 2 Disk Set tings page 111 For the volume for generation copy Snap Data Volume perform SnapOPC Destination Settings page 114 in 6 2 3 2 Disk Settings page 111 6 2 3 1 Disk Recognition The following procedure explains how to create a disk partition 1 Select Disk Management from Computer Management 2 If the Initialize Disk scre...

Страница 108: ... 3 Right click all the disks displayed as offline and select Online Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 108 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 109: ... disks to be changed to online and select Initialize Disk Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 109 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 110: ...d click the OK but ton 6 Confirm that the initialized disks are displayed as Online Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 110 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 111: ...explains how to set up the operation disk 1 Select Disk Management from Computer Management 2 On the New Simple Volume Wizard screen click the Next button Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 111 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 112: ...a drive letter and click the Next button Perform the settings as shown below Drive File system that is to be created LUN Volume No Volume name Type Capacity F NTFS 0 0 main Standard 1TB Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 112 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 113: ...appears Click the Finish button 7 Check that the specified settings are displayed correctly Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 113 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 114: ... in Snap Data Volume 1 During volume creation right click the disk created in Snap Data Volume and select New Simple Vol ume Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 114 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 115: ...ume Size click the Next button 4 Assign a drive letter in Assign Drive Letter or Path and click the Next button Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 115 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 116: ...6 6 sdv5 SDV 1TB M RAW 7 7 sdv6 SDV 1TB 1 The capacity that is displayed in is the copy source capacity 5 Select Do not format this volume and click the Next button 6 Completing the New Simple Volume Wizard appears Click the Finish button Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 116 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyrig...

Страница 117: ... Step 7 for all the disks created in Snap Data Volume In this case seven disks are created as Drive Letter Assigned RAW Chapter 6 SAN Connection Settings 6 2 Server Connection Setup 117 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 118: ...I screen Then click Setting in Category 2 In Action on the Setting screen click Modify EC OPC Priority 3 Select the EC OPC priority and click the Set button Automatic Priority This mode changes the EC OPC priority automatically in response to the operating load status High Priority This mode operates by making maximum use of internal resources This mode greatly affects host access performance thus...

Страница 119: ...ity mode 4 In the confirmation screen click the OK button EC OPC priority setting starts 5 In the setting completion screen click the Done button The screen display returns to the Setting Advanced Copy screen Chapter 7 Advanced Copy Settings 7 1 Advanced Copy Basic Settings 119 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3...

Страница 120: ...t at the beginning of the copy session To apply the changed resolution to a running copy session cancel the target copy session and then start the session again It is recommended to set the maximum resolution if the amount of data increase in the copy target area cannot be estimated 1 Click the Advanced Copy tab on the navigation of the ETERNUS Web GUI screen Then click Setting in Category 2 In Ac...

Страница 121: ...In the confirmation screen click the OK button Copy table size setting starts 5 In the setting completion screen click the Done button The screen display returns to the Setting Advanced Copy screen Chapter 7 Advanced Copy Settings 7 1 Advanced Copy Basic Settings 121 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05E...

Страница 122: ...ons cause an error Notification occurs only once for each policy level No notification is sent even if the threshold is reached within 24 hours from the previous notification Notification is sent after 24 hours have passed When the thresholds of multiple levels are reached at the same time the highest level of notification is sent 1 Click the Advanced Copy tab on the navigation of the ETERNUS Web ...

Страница 123: ...sideration of daily operations Copy session are first created for seven generations These copy sessions are switched in turn when daily backup operations are performed The procedure to perform the SnapOPC is as follows 1 On the navigation of the ETERNUS Web GUI screen click the Advanced Copy tab 2 In Action click Start SnapOPC 3 Click the Browse button of the copy source volume Chapter 7 Advanced ...

Страница 124: ...ain volume 5 In the same way as the copy source volume click the Browse button of the copy destination volume Chapter 7 Advanced Copy Settings 7 2 Performing a Copy SnapOPC 124 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 125: ... click the Start button 8 In the confirmation screen click the OK button The SnapOPC session starts 9 Click the Done button to return to the Advanced Copy screen Chapter 7 Advanced Copy Settings 7 2 Performing a Copy SnapOPC 125 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 126: ...ssions 12 Check the status of the copy source volume and the copy destination volume In this case the copy source volume number is 0 and the copy destination volume numbers are from 1 through to 7 13 Open Disk Management from Computer Management Chapter 7 Advanced Copy Settings 7 2 Performing a Copy SnapOPC 126 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic...

Страница 127: ...ending order of the drive let ters which results in discontinuous drive letters Change the automatically assigned drive letter if necessary 15 Check if the file that was created in Step 8 in Operation Disk Settings page 111 in 6 2 3 2 Disk Settings page 111 is displayed for the copy source drive Chapter 7 Advanced Copy Settings 7 2 Performing a Copy SnapOPC 127 FUJITSU Storage ETERNUS DX500 S3 DX6...

Страница 128: ...5 are displayed Old data can be restored by simply copying and pasting the data files that are to be restored from the server Chapter 7 Advanced Copy Settings 7 2 Performing a Copy SnapOPC 128 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Basic Copyright 2014 FUJITSU LIMITED P3AM 7732 05ENZ0 ...

Страница 129: ...ral status image is the ETERNUS DX is in normal status When the general status image is other than etc an abnormality has been detected in the ETER NUS DX Check the status of each component on the Storage screen If there is a component in Warning or Error status contact your sales representative or maintenance engi neer 129 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuratio...

Страница 130: ...r name of this RAID group 8 3 Volume Check On the Volume Details screen of ETERNUS Web GUI the status of volumes that you have created is dis played Check if volumes are set correctly To display the Volume Details screen click the Volume tab on the navigation of the ETERNUS Web GUI screen In the Volume Basic Information screen that appears select which volume to check the informa tion for and clic...

Страница 131: ...ons 8 5 Checking LUNs Check the LUN status from the server This section describes the check procedure using the ETERNUS Multipath Driver Click the Start button for Windows expand ETERNUS Multipath Driver from All Programs and open ETERNUS Multipath Manager Check that the LUN status is normal that the signal icon is blue Chapter 8 System Status Check 8 4 Checking Copy Sessions 131 FUJITSU Storage E...

Страница 132: ...TERNUS DX via the power synchronized unit When a power synchronized unit is connected the power of the ETERNUS DX is automatically turned on because the power synchronization function is activated If the REMOTE LED on the ETERNUS DX is green turn off the ETERNUS DX by linking with the server Pressing the Power switch does not turn off the ETERNUS DX To turn off the ETERNUS DX use the Power switch ...

Страница 133: ...RNUS DX power may turn on 2 The ETERNUS DX power is turned off The POWER LED of the controller enclosure and the POWER LEDs of the drive enclosures are turned off When a Power Synchronized Unit is Used If the server is turned off the ETERNUS DX is also turned off Chapter 8 System Status Check 8 6 Powering Off 133 FUJITSU Storage ETERNUS DX500 S3 DX600 S3 Disk storage system Configuration Guide Bas...

Страница 134: ...fer methods also enables flexible backup systems to be configured according to the operation environment Figure 9 1 Solution Continuous Business Copy Between ETERNUS DX Storage Systems WAN Business server SAN SAN Operation management server Gateway Gateway Standby ETERNUS DX ETERNUS DX CA RA CA RA CA RA CA RA Operation site Backup site ETERNUS SF AdvancedCopy Manager ETERNUS SF AdvancedCopy Manage...

Страница 135: ...hen an REC is performed in the Consistency mode The Consistency mode guar antees the order of data transfers to the connection destination storage system for all of the specified REC sessions REC disk buffer registration Set the REC disk buffer when REC buffer capacity is to be expanded Settings for ETERNUS SF AdvancedCopy Manager Register the following information in the operation management serv...

Страница 136: ...eration data Operation data Switch Switch ETERNUS DX Primary storage Mirrored data Mirrored data ETERNUS DX Secondary storage Operations can continue by switching to the Secondary storage The Storage Cluster controller detects a failure in the Primary storage ETERNUS SF Storage Cruiser Business server Operation data Operation data Switch Switch ETERNUS DX Primary storage Mirrored data Mirrored dat...

Страница 137: ...Cluster the ETERNUS SF Storage Cruiser Storage Cluster option is necessary A Storage Cluster controller is required to perform automatic failover Configuration Procedure Use ETERNUS SF Storage Cruiser to perform the following settings Registration of the ETERNUS DX License Registration Registration and configuration for servers and FC switches Storage Cluster configuration settings Operation volum...

Страница 138: ...ed and performance is improved In addition by automating operation data management hours and management costs can be reduced Figure 9 3 Solution Automated Storage Tiering High Low Operation volume Operation management server Monitors access frequency and automatically redistributes data to the optimal layer Automated Storage Tiering ETERNUS DX ETERNUS SF Storage Cruiser Access frequency SSD Fastes...

Страница 139: ...ge Cruiser to automate Quality of Service QoS This guarantees the bandwidth for a server according to the operation priority to reduce the effect on one server from another server which results in the performance of a server with high priority and important operations to be guaranteed In addition with Automated Storage Tiering resources can be used efficiently and storage costs can be opti mized B...

Страница 140: ...nd stabilized responses for prioritized operations Server C with high priority operations QoS automation Extreme Cache Server A with low priority operations Server B with low priority operations Response time ms Configuration Procedure Automated Storage Tiering Automated Storage Tiering can be achieved by using the ETERNUS DX Flexible Tier function and the ETERNUS SF Storage Cruiser functions QoS ...

Страница 141: ...ng Set the tiering policy and the virtual storage pool in the operation management server ETERNUS SF Storage Cruiser For details on the settings refer to ETERNUS SF Storage Cruiser Operation Guide for Optimization Option QoS automation Specify the target performance value for each volume in the operation management server ETERNUS SF Storage Cruiser For more details on the settings for ETERNUS SF S...

Страница 142: ...mperature as well as check the effect of power saving operations and the effect of air conditioning around the ETERNUS DX This statistical data can be output to a file so that it can be used when planning which power supply equipment and air conditioning equipment should be used by monitor ing the degree of changes in power consumption and temperature Figure 9 5 Solution Green Business drives Back...

Страница 143: ... management server ETERNUS SF Storage Cruiser or ETER NUS Web GUI Eco mode setup Enable the Eco mode for the ETERNUS DX Eco mode schedule setup Set the schedule to apply Eco mode Register the time period to turn on the disk motors or turn on the disk power for backups as well as the RAID group that contains these target disks Visualization of the power consumption and the temperature Register the ...

Страница 144: ... Administrator ETERNUS Oracle VM Storage Connect Plug in Oracle VM ETERNUS Oracle VM Storage Connect Plug in Configuration Procedure Install any plug ins that are required for Oracle VM linkage and perform the necessary settings Required Environment For linkage with Oracle VM Manager ETERNUS Oracle VM Storage Connect Plug in is required An Advanced Copy Feature license is also required Configurati...

Страница 145: ...reness VASA can enhance the VMware storage management function Figure 9 7 Solution Virtualization Platform VMware Linkage VM management server Storage management server VMware App OS App OS App OS VMware App OS App OS App OS VMware vSphere Web Client VMware vCenter Server SAN Status check of the ETERNUS DX Profile Driven Storage Storage DRS ETERNUS DX Web Client Server ETERNUS VASA Provider ETERNU...

Страница 146: ...VASA Provider in the vCenter Server after installation Settings for ETERNUS SF Storage Cruiser Before starting the ETERNUS VASA Provider service register ESXi Server and the ETERNUS DX that is to be monitored in ETERNUS SF Storage Cruiser Update the configuration file and enable linkage with the device event information to apply the ETERNUS VASA Provider settings For more details on the settings f...

Страница 147: ...ired Environment For linkage with System Center 2012 no plug ins are required Configuration Procedure SCVMM2012 Use ETERNUS Web GUI to enable the SMI S settings in the ETERNUS DX If the management console for SCVMM2012 uses a different subnet add the subnet to Allowed IP List in Set Network Environment When Windows Server 2012 is installed in the Hyper V server the ODX function is available for da...

Страница 148: ...log System administrator Auditor ETERNUS DX SED SED SED SED RAID group 0 SED SED SED SED RAID group 1 ETERNUS SF KM The authentication key is updated periodically according to the specified schedule Key server Configuration Procedure Use the ETERNUS DX to enable the audit log transmission function and to register the Syslog server as the destination to which audit logs are sent When key management...

Страница 149: ...rver certificate import Register the SSL KMIP server side certificate that is exported from the key server in the ETERNUS DX SED authentication key update Obtain the key that is set to the key group from the server Creating the key group Register the RAID groups that use the same key in the key group Settings for ETERNUS SF KM Register the following information in the key server ETERNUS SF KM SSL ...

Страница 150: ...pared with the utmost attention to detail However Fujitsu shall assume no responsibility for any operational problems as the result of errors omissions or the use of information in this manual Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual The content of this manual may not be reproduced or distributed in pa...

Страница 151: ......