Reverse Cabling
Because the ETERNUS DX uses reverse cabling connections for data transfer paths between controllers and
drives, continued access is ensured even if a failure occurs in a drive enclosure.
If a drive enclosure fails for any reason, access to drives that are connected after the failed drive can be main-
tained because normal access paths are secured by using reverse cabling.
Figure 20 Reverse Cabling
CM#0
CM#1
CE
IOM#0
IOM#1
DE#00
IOM#0
IOM#1
DE#01
IOM#0
IOM#1
DE#02
IOM#0
IOM#1
DE#03
IOM#0
IOM#1
DE#04
IOM#0
IOM#1
DE#05
IOM#0
IOM#1
DE#05
CM#0
CM#1
CE
IOM#0
IOM#1
DE#00
IOM#0
IOM#1
DE#01
IOM#0
IOM#1
DE#02
IOM#0
IOM#1
DE#03
IOM#0
IOM#1
DE#04
Failure
Reverse cabling connection
(Connect the controller enclosure to the last drive enclosure)
Continued access is available to drives
in the drive enclosures that follow the failed one.
A failure occurs
in a drive enclosure
:
Accessible
:
Inaccessible
2. Basic Functions
Data Protection
41