IP addresses of the LAN ports are not assigned to each CM. These IP addresses are assigned to the role of master
or slave. If the Master CM is switched, the same IP addresses are reused. Therefore, even if the Master CM is
switched and the physical port is changed, access can be maintained via the same IP addresses. The MAC ad-
dress is not inherited.
Figure 102 LAN Control (Switching of the Master CM)
ETERNUS DX
ETERNUS DX
The Master CM is switched.
Controller enclosure
MNT
CM#0
Master CM
MNT
CM#1
Slave CM
RMT
FS
T
FS
T
RMT
IP address A
IP address A
Controller enclosure
MNT
CM#0
Slave CM
MNT
CM#1
Master CM
RMT
FS
T
FS
T
RMT
CM#0
has failed
When the Master CM is
switched, the IP addresses of
the previous Master CM are
taken over by the new
Master CM.
•
Each CM has an LED that lights up green to identify when it is the Master CM.
•
Setting the IP address of the Slave CM ensures that ETERNUS Web GUI or ETERNUS CLI can be used from the
Slave CM if an error occurs on the LAN path for the Master CM.
The Master CM and the Slave CM perform different functions. The Slave CM can only switch the Master CM
and display the status of the ETERNUS DX.
The IP address of the Slave CM does not need to be set for normal operation.
Figure 103 LAN Control (When the IP Address of the Slave CM Is Set)
Controller enclosure
MNT
CM#0
Master CM
CM#1
Slave CM
RMT
FS
T
FS
T
RMT
ETERNUS DX
LAN path
error
MNT
The IP address of the Slave CM is
used to switch the Master CM and
display the status of the ETERNUS DX.
IP address A
IP address B
4. Connection Configuration
LAN Connection
159
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED