The target drives are deactivated and then reactivated during temporary drive protection. Even though a
system status error may be displayed during this period, this phenomenon is only temporary. The status
returns to normal after the diagnosis is complete.
The following phenomenon may occur during temporary drive protection.
-
The Fault LEDs (amber) on the operation panel and the drive turn on
-
An error status is displayed by the ETERNUS Web GUI and the ETERNUS CLI
•
Error or Warning is displayed as the system status
•
Error, Warning, or Maintenance is displayed as the system status
•
Target drives of the Protection (Shield) function only need to be replaced when drive reactivation fails.
If drive reactivation fails, a drive failure error is notified as an event notification message (such as SNMP/
REMCS). When drive reactivation is successful, an error message is not notified. To notify this message, use
the event notification settings.
•
To set the Protection (Shield) function for each storage system, use the subsystem parameter settings. The
maintenance operation privilege is required to perform this setting.
After the settings are changed, the ETERNUS DX does not need to be turned off and on again.
2. Basic Functions
Data Protection
40
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
P3AM-7722-25ENZ0