Chapter 7 Example
7.1 Configuration and Generation of an ETERNUS DX8700 S3 for BS2000 (SE Server)
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-
Copyright 2018 FUJITSU LIMITED
P3AM-5672-10ENZ0
25
■
Defining the Host Response
Connectivity > Host response
Add Host Response
For the host connection, a host response with the name "BS2000" is predefined in the "Host Response
Parameters".
■
Configuring settings for FC ports
Connectivity > Port Group
Create FC Port
The CA parameters are defined for each of the 4 FC ports. The transfer rate is set to 8Gbit/s.
4 Port Groups are registered in the ETERNUS DX8700 S3:
■
Registering Host WorldWideName(s)
Connectivity > Host Group > FC/FCoE
Add FC/FCoE Host
The WWPNs of the 4 SE700 FC channels are registered in the ETERNUS DX8700 S3 at the corresponding FC
ports:
The logical volumes will now be configured via the following steps and combined in affinity groups:
■
Configuring RAID groups
RAID Group
Create
4 RAID groups from RG01 to RG04 are set up. The assignment of the RAID groups to the CPUs is made
manually as follows:
CA Port Group
Port Group Member
PG0000
CE#0 CM#0 CA#0 Port#0
PG1011
CE#1 CM#0 CA#1 Port#1
PG0111
CE#0 CM#1 CA#1 Port#1
PG1000
CE#1 CM#0 CA#0 Port#0
FC Host
WWN
Host Group
SE700 47
204700000EA00CE3
S_1011_F1
SE700 4A
204A00000EA00CE3
S_0000_F1
SE700 0D
200D00000EA00CE3
S_0111_F2
SE700 04
200400000EA00CE3
S_1000_F2
RAID group
CM#
CPU#
RAID Type
RG01
0
0
RAID1
RG02
1
0
RAID1
RG03
0
1
RAID1
RG04
1
1
RAID1
Содержание ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF