2. Rack Installation Specifications
Installable Racks
Site Planning Guide
66
Figure 47 Unit Installation Area
Table 31 Specifications for the Unit Installation Area
*1: For the DS460C, the recommended depth of the rack space is equal to the depth of the shelf body (922 mm) + 60
mm or more because the cable connection interface has depth of 40 mm from the rear surface of the shelf.
■
Installation Requirements
When determining service areas, refer to the manual of the rack that is to be used.
Be sure to perform the installation according to the requirements described in
"Installation Specifications" (page
and
"Installation Environment" (page 30)
Specification
Condition
(1)
Rack front space
(Space between the fixed part of the ETERNUS AX/HX on
the front side and the front of the rack)
50 mm or more
(2)
Mount bracket length
(Size between each end of the front and rear rack pillars)
600 mm to 790 mm
(3)
Rack space
(Space between the fixed part of the ETERNUS AX/HX on
the front side and the rear of the rack)
The depth of the shelf body (*1) + 100 mm or
more (recommended for the extra cable
length)
(4)
Rack mount kit installation area
483 mm or more (recommended)
ETERNUS
(1)
(2)
(3)
(4)
Rear door of the rack
Front door of the rack
Rack pillars
Rack rails
Top
Содержание ETERNUS AX Series
Страница 68: ......