1. ETERNUS AX/HX Installation
Installation Environment
Site Planning Guide
31
Installation Methods
•
Perform one of the following rack installation methods to ensure the safe use of an ETERNUS AX/HX that is
installed in a rack:
-
To secure a rack, use a rack without stabilizers and secure it to the building with the leveling feet.
-
If a rack is not to be secured, make sure to use a rack with stabilizers and use these stabilizers to prevent
the rack from toppling over.
•
The installation method that should be used depends on the installation location, the floor conditions, and
the type of racks where the ETERNUS AX/HX is to be installed. Contact your installation contractor for more
details regarding installation and how the installation should actually be performed.
An installation diagram when installing a rack (or the floor dimensions of the rack) is shown below.
Figure 14 Floor Dimensions of the Rack (of 19-inch Racks)
919 mm (leveling feet)
733 mm (caster)
Front
Rear
523 mm (caster)
350 mm
570 mm (leveling feet)
175 mm
700 mm
1,050 mm
1,013 mm
95 mm
826 mm
65 mm
89
mm
47 mm
140 mm
Caster
Leveling feet
Cable slot