En-4
2.4. Accessories
The following installation accessories are supplied. Use
them as required.
Name and Shape
Q’ty
Name and Shape
Q’ty
Operating Manual
1
Remote controller
holder
1
Installation Manual
(This manual)
1
Cloth tape
1
Wall hook bracket
1
Tapping screw
(big)
8
Remote controller
1
Tapping screw
(small)
2
Battery
2
Air cleaning filter
2
The following items are necessary to install this air condi-
tioner. (The items are not included with the air conditioner
and must be purchased separately.)
Name Q’ty
Connection pipe assembly
1
Connection cable (4-conductor)
1
Wall pipe
1
Decorative tape
1
Vinyl tape
1
Wall cap
1
Saddle
1 set
Drain hose
1
Tapping screws
1 set
Sealant
1
2.5. Optional parts
Refer to each installation manual for the method of installing
optional parts.
Parts name
Model No.
Application
Wired Remote
Controller *
UTY-
RNNUM
For air conditioner
operation
Wireless Remote
Controller
UTY-
LNHUM
For air conditioner
operation
Simple Remote
Controller *
UTY-
RSNUM
For air conditioner
operation
External connect kit *
UTY-
XWZX
For control input/output
port
Communication kit
UTY-
XCBXZ1
For the installation of
optional parts
* Optional communication kit is necessary for the installation.
3. GENERAL
This INSTALLATION MANUAL briefly outlines where and how to
install the air conditioning system. Please read over the entire set
of instructions for the indoor and outdoor units and make sure all
accessory parts listed are with the system before beginning.
3.1. Type of copper pipe and insulation
material
CAUTION
Refer to the installation manual for the outdoor unit for
description of allowable pipe length and height difference.
Diameter
Liquid pipe
Gas pipe
6.35 mm (1/4 in.)
9.52 mm (3/8 in.)
CAUTION
Install heat insulation around both the gas and liquid
pipes. Failure to do so may cause water leaks.
Use heat insulation with heat resistance above 248 °F.
Reverse cycle model only)
In addition, if the humidity level at the installation lo-
cation of the refrigerant piping is expected to exceed
70%, install heat insulation around the refrigerant pip-
ing. If the xpected humidity level is 70-80%, use heat
insulation that is 15 mm (19/32 in.) or thicker and if the
expected humidity exceeds 80%, use heat insulation
that is 20 mm (25/32 in.) or thicker.
If heat insulation is used that is not as thick as speci- ed,
condensation may form on the surface of the insulation.
In addition, use heat insulation with heat conductivity
of 0.045 W/(m•K) or less (at 68 °F).
3.2. Additional materials required for
installation
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire (See your
local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping
9332279030-04_IM.indb 4
9332279030-04_IM.indb 4
9/8/2010 9:56:05 AM
9/8/2010 9:56:05 AM