7.4
Detach RU Mounting Adapter Plate
This procedure describes how to detach the mounting adapter plate from the RU.
Prerequisites:
■
Loctite LB 8012 or equivalent lubricant applied to all bolts
■
17 mm socket
■
5/8 in. wrench
■
Power tools (optional)
■
Metric and SAE toolkit
Step 1
Unscrew the two M10 x 30 bolts from the front of the mounting adapter plate.
FNC00160
1_R
ev_03
Figure 59
Removing Bolts from Mounting Adapter Plate
Step 2
Remove the flat and split washers, insulating bushings, and mounting plate from the RU.
Removal
Detach RU Mounting Adapter Plate
164
Release 1.0
·