5.1
Check Connections and DC Power Polarity
This procedure describes how to perform checks before turning on the power.
Step 1
Verify that all necessary cables are connected to the RU.
Step 2
Check the polarity of Pin A on the DC power supply, which should read –48 V.
Note:
The RU does not have a power switch. DC power is controlled by a circuit breaker at the DC power source.
Do not turn on the circuit breaker until it's time to power up the RU.
Note:
It takes less than one minute for the RU to fully power up.
Step 3
Verify weatherproofing is applied to each cable connector according to local guidelines.
Note:
Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL
approved weatherproofing material. Refer to
Weatherproofing RU Connections
for more information about
weatherproofing methods.
Continue with the next task.