En-9

3. 6. Electrical wiring

 

WARNING

•  Electrical work must be performed in accordance with this Manual by a person certi-

fi

 ed under the national or regional regulations. Be sure to use a dedicated circuit for 

the unit. 
An insuf

fi

 cient power supply circuit or improperly performed electrical work can 

cause serious accidents such as electric shock or 

fi

 re.

•  Before starting work, check that power is not being supplied to the indoor unit and outdoor 

unit.

•  Use the included connection cables and power cables or ones speci

fi

 ed by the man-

ufacturer. Improper connections, insuf

fi

 cient insulation, or exceeding the allowable 

current can cause electric shock or 

fi

 re.

•  For wiring, use the prescribed type of cables, connect them securely, making sure 

that there are no external forces of the cables applied to the terminal connections. 
Improperly connected or secured cables can cause serious accidents such as over-
heating the terminals, electric shock, or 

fi

 re.

•  Do not modify the power cables, use extension cables, or use any branches in the 

wiring. Improper connections, insuf

fi

 cient insulation, or exceeding the allowable cur-

rent can cause electric shock or 

fi

 re.

•  Match the terminal board numbers and connection cable colors with those of the 

outdoor unit. Erroneous wiring may cause burning of the electric parts.

•  Securely connect the connection cables to the terminal board. In addition, secure 

the cables with wiring holders. Improper connections, either in the wiring or at the 
ends of the wiring, can cause a malfunction, electric shock, or 

fi

 re.

•  Always fasten the outside covering of the connection cable with the cable clamp. (If 

the insulator is chafed, electric leakage may occur.)

•  Securely install the electrical box cover on the unit. An improperly installed electrical box 

cover can cause serious accidents such as electric shock or 

fi

 re through exposure to dust or 

water.

•  Install sleeves into any holes made in the walls for wiring. Otherwise, a short circuit could 

result.

•  Install a earth (ground) leakage breaker. In addition, install the earth (ground) leak-

age breaker so that the entire AC main power supply is cut off at the same time. 
Otherwise, electric shock or 

fi

 re could result.

•  Always connect the earth (ground) cable.

Improper earthing (grounding) work can cause electric shocks.

•  Install the remote controller cables so as not to be touched directly with your hand.
•  Perform wiring work in accordance with standards so that the air conditioner can be 

operated safely and positively.

•  Unit shall be earthed (grounded) in compliance with the applicable local and national 

codes.

 

CAUTION

•  If the indoor unit connection cable and power supply are wired incorrectly, the air 

conditioner may be damaged or cause malfunction.

•  Ground the unit.

Do not connect the earth (ground) cable to a gas pipe, water pipe, lightning rod, or a 
telephone earth (ground) cable. 
Improper earthing (grounding) may cause electric shock.

•  Do not connect power supply cables to the transmission or remote controller termi-

nals, as this will damage the product.

•  Never bundle the power supply cable and transmission cable together. Bundling 

these cables together will cause miss operation.

•  When handling PCB, static electricity charged in the body may cause malfunction of 

the PCB. Follow the cautions below:
 

̵

Establish a ground for the indoor and outdoor units and peripheral devices.

 

̵

Cut power (breaker) off.

 

̵

Touch metal part of the indoor and outdoor units for more than 10 seconds to 
discharge static electricity charged in the body.

 

̵

Do not touch terminals of parts and patterns implemented on PCB.

•  Be careful not to generate a spark as follows for using a 

fl

 ammable refrigerant.

 

̵

Do not remove the fuse while power is on.

 

̵

Do not disconnect plug from the wall outlet and the wiring while the power is on.

 

̵

It is recommended to position the outlet connection in a high position. Place the 
cords so that they do not get tangled.

3.6.1. Wiring system diagram

Connection cable to outdoor unit

Wired remote controller cable

2-wire type

Red

Red

White

White
Black

3-wire type

or

Earth (ground) line

Power line

Control line

3.6.2. Connection cable preparation

 

Connection cable

Earth (ground) 
wire

Keep the earth (ground) wire longer than the other wires.

• Use a 4-core wire cable.

Connection cable

40 mm or more

30 mm

 

Remote controller cable

For 2-wire type

For 3-wire type

30 mm

30 mm

3.6.3. How to connect wiring to the terminals. 

(1)  Use ring terminals with insulating sleeves as shown in the 

fi

 gure below to connect to 

the terminal block.

(2)  Securely crimp the ring terminals to the wires using an appropriate tool so that the 

wires do not come loose.

 

Strip 10 mm

Ring terminal

Sleeve

(3) Use the speci

fi

 ed wires, connect them securely, and fasten them so that there is no 

stress placed on the terminals.

(4)  Use an appropriate screwdriver to tighten the terminal screws.

Do not use a screwdriver that is too small, otherwise, the screw heads may be 
damaged and prevent the screws from being properly tightened.

(5)  Do not tighten the terminal screws too much, otherwise, the screws may break.
(6)  See the table below for the terminal screw tightening torques.

 

WARNING

Use ring terminals and tighten the terminal screws to the speci

fi

 ed torques, otherwise, 

it may cause abnormal overheating and possibly cause serious damage inside the 
unit.

Tightening torque [N·m (kgf·cm)]

M4 screw

1.2 to 1.8 (12 to 18)

Screw with 
special washer

Ring terminal

Terminal blocks

Wire

Wire

Screw with 
special 
washer

Ring terminal

381798070_IM.indb   9

381798070_IM.indb   9

12/5/2018   9:39:32 AM

12/5/2018   9:39:32 AM

Содержание AUXG-KRLB Series

Страница 1: ... and use the power cable combined with an Earth Leakage Circuit Breaker ELCB This product is not explosion proof and therefore should not be installed in an explo sive atmosphere To avoid getting an electric shock never touch the electrical components soon after the power supply has been turned off After turning off the power always wait 5 min utes or more before you touch the electrical component...

Страница 2: ... which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possibly be...

Страница 3: ...g the system it shall be pressure tested with OFN The system shall be leak tested on completion of charging but prior to commission ing A follow up leak test shall be carried out prior to leaving the site CAUTION 10 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its details It is recommended good practice tha...

Страница 4: ... the manufacturer or other prescribed parts The use of non prescribed parts can cause serious accidents such as the unit falling water leakage electric shock or fire Do not turn on the power until all work has been completed CAUTION This manual describes how to install the indoor unit only To install the outdoor unit or branch box if any refer to the installation manual included in each product 2 ...

Страница 5: ...door unit in the following areas Area with high salt content such as at the seaside It will deteriorate metal parts causing the parts to fall or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam such as a kitchen It will deteriorate plastic parts causing the parts to fall or the unit to leak water Area that generates substances that adversely...

Страница 6: ...g and durable ceiling 3 or more Floor Obstruction Unit m 1 5 or more 1 8 or more 1 or more This product can be installed at a height of up to 4 2 m However if the heights of the ceiling is higher than 3 2 m or lower than 2 7 m it is necessary to set the position from remote controller Refer to 7 FUNCTION SETTING Discharge direction setting Unit mm The discharge direction can be selected as shown b...

Страница 7: ...ble to have sufficient gradient of pipe perform drain lift up Pipe size Drain pipe VP25 O D 32 mm Hanging fittings 1 5 to 2 m VP25 O D 32 mm Downward gradient 1 100 to 1 50 Rise PROHIBITED Trap Air bleeding When lifting up drain Height of inclined pipe should be less than 850 mm from the ceiling A rise dimension over this range will cause leakage Lift up the pipe vertically at the position of 300 ...

Страница 8: ... 0 When using conventional flare tools to flare R32 pipes the dimension A should be approxi mately 0 5 mm more than indicated in the table for flaring with R32 flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 N...

Страница 9: ...the air conditioner may be damaged or cause malfunction Ground the unit Do not connect the earth ground cable to a gas pipe water pipe lightning rod or a telephone earth ground cable Improper earthing grounding may cause electric shock Do not connect power supply cables to the transmission or remote controller termi nals as this will damage the product Never bundle the power supply cable and trans...

Страница 10: ... as shown in terminal label Be sure to refer to the connection diagram for the correct field wiring Wrong wiring causes malfunction of the unit 3 6 5 Connection wiring CAUTION Be careful not to mistake the power supply cable and connection wires when install ing Install so that the wires for the remote controller will not come in contact with other connection wires 1 Remove the control box cover a...

Страница 11: ...Stop mode or Forced stop mode can be selected with function setting of indoor unit A twisted pair cable 22 AWG should be used Maximum length of cable is 150 m 492 ft Use an external input and output cable with appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Connected device Terminal Dry contact termin...

Страница 12: ...manual or the operating manual supplied with the air conditioner Setting the switches other than specified will cause an accident or trouble Do not touch the circuit board and circuit board parts directly with your hands Oth erwise injury or electric shock could result Use an insulated screwdriver to set the dip switches 6 1 Group control CAUTION Group control is only possible between units with r...

Страница 13: ...h 2 Wired Type A I U A B I U Master Master Slave A B Remote controller cable Refer to 2 4 Electrical requirement A 500 m A B 500 m 7 FUNCTION SETTING Refer to the installation manual of remote controller for setting method 7 1 Function Details Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room ...

Страница 14: ... number Setting value Setting description 42 00 Indoor unit 01 Both 00 Sensor on the indoor unit is active 01 Sensors on both indoor unit and wired remote controller are active Remote controller sensor must be turned on by using the remote controller Remote controller custom code Only for wireless remote controller The indoor unit custom code can be changed Select the appropriate custom code Facto...

Страница 15: ...he operating manual of the wired remote controller The Operation indicator lamp and Timer indicator lamp will simultaneously flash during the test run mode Heating test run will begin in a few minutes when HEAT is selected by the remote controller reverse cycle model only 10 FINISHING CAUTION After checking for gas leaks refer to the Installation Manual of the outdoor unit perform this section Ins...

Страница 16: ... Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor error Error display Wired remote controller Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 8 2 Sub cool Heat Ex gas inlet temp senso...

Отзывы: