• Refrigerant piping and drain piping positions. 

Unit: mm

Liquid pipe

293

45

342

200

140

180

80

Gas pipe

Drain pipe
(Connect the 
attached drain 
hose)

10

• Distribution ducts and fresh air inlet positions. 

Unit: mm

Distribution duct connecting port

Detailed diagram of distribution duct 
connecting port (4 sides)

bolt pitch

Cut out

Cut out

 95

237

 114

100

100

83

83

352

90

163

163

Fresh air inlet position

10 ×   3.2 hole 

4 ×   3.2 hole 

Distribution duct

 

connecting port

Distribution duct connecting port

Distribution duct connecting port

Fresh air inlet 

position

Drain pipe

Refrigerant pipe

NOTES:

Conduct proper insulation when connecting the distribution ducts and fresh air inlet.

Insulation

Fresh air inlet position

NOTES:

When introducing fresh air into the indoor unit, please remove the insulation af

fi

 xed to the 

drain pan.

(2) Setting the positions of hanging bolt and ceiling opening.

• Use an installation template (packaging top surface) to set the positions of the hanging 

bolt and ceiling opening and drill holes.

(3) Hanging structure.

• Select a strong structure for the hanging location.
• If necessary, reinforce the hanging bolt with quake proof columnar support material to 

prevent shaking.

• Use hanging bolts of M8-M10.

3.3.2. Body installation

(1) Install the attached washer and nut (prepared on site) onto the hanging bolt.
(2) Hook the body onto the hanging bolt.
(3) Adjust the dimensions of the ceiling surface from the body. After installing the Cassette 

grille, you can make 

fi

 ne adjustment of the height of the body. For details, refer to the 

installation manual of the Cassette grille.

 WARNING

• Perform 

fi

 nal tightening by tightening the double nut 

fi

 rmly.

•  Be sure to install the body horizontally and adjust the height below the body and the 

ceiling surface properly.

3. 2. Installation dimension

• The ceiling rear height as shown in the 

fi

 gure.

Strong and durable ceiling

3 or more

Floor

Obstruction

Unit: m

1.5 or 

more

1.8 or more

1 or more

• This product can be installed at a height of up to 4.2 m. However, if the heights of the 

ceiling is higher than 3.2 m or lower than 2.7 m, it is necessary to set the position from 
remote controller. (Refer to “7. FUNCTION SETTING”)

Discharge direction setting

 

Unit : mm

• The discharge direction can be selected as shown below.

100 or more*

(4 directions)

(3 directions) 

*  Please ensure suf

fi

 -

cient service access 
during installation.

•  For a 3-way outlet, make sure to perform the function setting on the remote control. 

Also, make sure to use the optional shutter plate to block the outlet.

•  The ceiling height cannot be set in the 3-way outlet mode. Therefore, do not change the 

setting in the setting the ceiling height. (Refer to “7. FUNCTION SETTING”)

•  When the outlet is shut, be sure to install the optional Air outlet shutter plate kit. For the 

details of installation, please refer to installation manual of the kit.

3. 3. Installing the unit

 

WARNING

•  Carrying and installation of the unit should be performed by a suf

fi

 cient number 

of people and with suf

fi

 cient equipment that is adequate for the weight of the unit. 

Performing such work with an insuf

fi

 cient number of people or with inadequate 

equipment could result in dropping of the unit or personal injury.

•  If the job is done with the panel frame only, there is a risk that the unit will come 

loose. Please take care.

•  When fastening the hangers, make the bolt positions uniform.

3.3.1. Position the ceiling hole and hanging bolts

(1)  Positions of the ceiling opening, hanging bolt pitch, piping and ducts. 

• Ceiling opening and hanging bolt pitch. 

Unit: mm

Model

Dimension (mm)

A

B

18/22/24

246

256

30/36/45/54

288

298

950(Panel frame) 

860 - 910(Ceiling opening) 

 768(Hanging bolt pitch) 

840(Body frame)

860 - 910(Ceiling opening)

950(Panel frame) 

840(Body frame)

796(Hanging bolt pitch)

20 - 45

20 - 45

50

200

20 - 45

20 - 45

130

130

130

80

200 - 205

39

10

A

B

50 - 100

381798070_IM.indb   6

381798070_IM.indb   6

12/5/2018   9:39:32 AM

12/5/2018   9:39:32 AM

Содержание AUXG-KRLB Series

Страница 1: ... and use the power cable combined with an Earth Leakage Circuit Breaker ELCB This product is not explosion proof and therefore should not be installed in an explo sive atmosphere To avoid getting an electric shock never touch the electrical components soon after the power supply has been turned off After turning off the power always wait 5 min utes or more before you touch the electrical component...

Страница 2: ... which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possibly be...

Страница 3: ...g the system it shall be pressure tested with OFN The system shall be leak tested on completion of charging but prior to commission ing A follow up leak test shall be carried out prior to leaving the site CAUTION 10 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its details It is recommended good practice tha...

Страница 4: ... the manufacturer or other prescribed parts The use of non prescribed parts can cause serious accidents such as the unit falling water leakage electric shock or fire Do not turn on the power until all work has been completed CAUTION This manual describes how to install the indoor unit only To install the outdoor unit or branch box if any refer to the installation manual included in each product 2 ...

Страница 5: ...door unit in the following areas Area with high salt content such as at the seaside It will deteriorate metal parts causing the parts to fall or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam such as a kitchen It will deteriorate plastic parts causing the parts to fall or the unit to leak water Area that generates substances that adversely...

Страница 6: ...g and durable ceiling 3 or more Floor Obstruction Unit m 1 5 or more 1 8 or more 1 or more This product can be installed at a height of up to 4 2 m However if the heights of the ceiling is higher than 3 2 m or lower than 2 7 m it is necessary to set the position from remote controller Refer to 7 FUNCTION SETTING Discharge direction setting Unit mm The discharge direction can be selected as shown b...

Страница 7: ...ble to have sufficient gradient of pipe perform drain lift up Pipe size Drain pipe VP25 O D 32 mm Hanging fittings 1 5 to 2 m VP25 O D 32 mm Downward gradient 1 100 to 1 50 Rise PROHIBITED Trap Air bleeding When lifting up drain Height of inclined pipe should be less than 850 mm from the ceiling A rise dimension over this range will cause leakage Lift up the pipe vertically at the position of 300 ...

Страница 8: ... 0 When using conventional flare tools to flare R32 pipes the dimension A should be approxi mately 0 5 mm more than indicated in the table for flaring with R32 flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 N...

Страница 9: ...the air conditioner may be damaged or cause malfunction Ground the unit Do not connect the earth ground cable to a gas pipe water pipe lightning rod or a telephone earth ground cable Improper earthing grounding may cause electric shock Do not connect power supply cables to the transmission or remote controller termi nals as this will damage the product Never bundle the power supply cable and trans...

Страница 10: ... as shown in terminal label Be sure to refer to the connection diagram for the correct field wiring Wrong wiring causes malfunction of the unit 3 6 5 Connection wiring CAUTION Be careful not to mistake the power supply cable and connection wires when install ing Install so that the wires for the remote controller will not come in contact with other connection wires 1 Remove the control box cover a...

Страница 11: ...Stop mode or Forced stop mode can be selected with function setting of indoor unit A twisted pair cable 22 AWG should be used Maximum length of cable is 150 m 492 ft Use an external input and output cable with appropriate external dimension depending on the number of cables to be installed The wire connection should be separate from the power cable line Connected device Terminal Dry contact termin...

Страница 12: ...manual or the operating manual supplied with the air conditioner Setting the switches other than specified will cause an accident or trouble Do not touch the circuit board and circuit board parts directly with your hands Oth erwise injury or electric shock could result Use an insulated screwdriver to set the dip switches 6 1 Group control CAUTION Group control is only possible between units with r...

Страница 13: ...h 2 Wired Type A I U A B I U Master Master Slave A B Remote controller cable Refer to 2 4 Electrical requirement A 500 m A B 500 m 7 FUNCTION SETTING Refer to the installation manual of remote controller for setting method 7 1 Function Details Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room ...

Страница 14: ... number Setting value Setting description 42 00 Indoor unit 01 Both 00 Sensor on the indoor unit is active 01 Sensors on both indoor unit and wired remote controller are active Remote controller sensor must be turned on by using the remote controller Remote controller custom code Only for wireless remote controller The indoor unit custom code can be changed Select the appropriate custom code Facto...

Страница 15: ...he operating manual of the wired remote controller The Operation indicator lamp and Timer indicator lamp will simultaneously flash during the test run mode Heating test run will begin in a few minutes when HEAT is selected by the remote controller reverse cycle model only 10 FINISHING CAUTION After checking for gas leaks refer to the Installation Manual of the outdoor unit perform this section Ins...

Страница 16: ... Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor error Error display Wired remote controller Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 8 2 Sub cool Heat Ex gas inlet temp senso...

Отзывы: