- 47 -
O
U
T
D
OOR UNIT
AOTG09-12L
BCB
5. Capacity compensation rate for pipe length and height
difference
5-1. Models: AOTG09LBCB and AOTG12LBCB
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
15
20
Height differenc
e
H (m)
Indoor unit is higher than
outdoor unit *1
15
—
—
—
0.877
0.873
10
—
—
0.955
0.892
0.888
7.5
—
0.988
0.959
0.895
0.891
5
0.992
0.992
0.963
0.899
0.895
0
1.000
1.000
0.971
0.906
0.902
Indoor unit is lower than outdoor
unit *2
-5
1.000
1.000
0.971
0.906
0.902
-7.5
—
1.000
0.971
0.906
0.902
-10
—
—
0.971
0.906
0.902
-15
—
—
—
0.906
0.902
HEATING
Pipe length (m)
5
7.5
10
15
20
He
igh
t differ
ence
H (m)
Indoor unit is higher than
outdoor unit *1
15
—
—
—
0.933
0.925
10
—
—
0.981
0.933
0.925
7.5
—
1.000
0.981
0.933
0.925
5
1.000
1.000
0.981
0.933
0.925
0
1.000
1.000
0.981
0.933
0.925
Indoor unit is lower than outdoor
unit *2
-5
0.995
0.995
0.976
0.928
0.920
-7.5
—
0.993
0.974
0.926
0.918
-10
—
—
0.971
0.924
0.916
-15
—
—
—
0.914
0.907
Height difference H
Indoor unit is higher than outdoor unit
*
1
Indoor unit is lower than outdoor unit
*
2
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
Содержание AUTG09LVLB
Страница 5: ...Part 1 INDOOR UNIT CASSETTE TYPE AUTG09LVLB AUTG12LVLB ...
Страница 16: ... 12 CASSETTE TYPE AUTG09 12LVLB 5 Wiring diagram 5 1 Models AUTG09LVLB and AUTG12LVLB ...
Страница 26: ... 22 CASSETTE TYPE AUTG09 12LVLB 8 2 Sound level check point Microphone Microphone Center 1 5 m Center ...
Страница 42: ... 38 CASSETTE TYPE AUTG09 12LVLB ...
Страница 43: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOTG09LBCB AOTG12LBCB ...
Страница 45: ... 41 OUTDOOR UNIT AOTG09 12LBCB 2 Dimensions 2 1 Models AOTG09LBCB and AOTG12LBCB Unit mm ...
Страница 50: ... 46 OUTDOOR UNIT AOTG09 12LBCB 4 Wiring diagrams 4 1 Models AOTG09LBCB and AOTG12LBCB ...