01-15
17. COMPRESSOR PREHEATING
18. 10°C
HEAT OPERATION
10°C HEAT operation performs as below when pressing 10°C HEAT button or Weekly timer setting
on the remote controller.
Mode Heating
Setting temperature 10
°C
Fan mode Auto
LED display Economy
Defrost operation Operate as normal
( Table 19 : 10°C HEAT operation )
19.
ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
At the maximum output, ECONOMY Operation is approximately 70% of normal air conditioner operation
for cooling and heating.
The ECONOMY operation is almost the same operation as below settings.
Mode Cooling/ Dry Heating
Target temperature Setting temp.+1°C Setting temp.-1°C
( Table 20 )
When the outdoor heat exchanger temperature is lower than 5
°C
and the all operation has been
stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor temperature rises to 7
°C
or greater,
preheating is ended.
20.
OUTDOOR UNIT LOW NOISE OPERATION
The OUTDOOR UNIT LOW NOISE Operation functions by pressing OUTDOOR UNIT LOW NOISE button
on the remote controller.
This operation stops the PFC control, and changes the Current release operation/release value.
OUTDOOR UNIT LOW NOISE Operation mode can be used during cooling, heating and automatic operation.
It can not be used in Fan and Dry mode
Control / Release
Current release
operation/release value
3.5A / 3.0A
( Table 21 )
Содержание AOYG07LMCE
Страница 4: ...2016 11 21 3 OUTDOOR UNIT 15 663 mm 20 293 mm 68 454 mm 535 mm ...
Страница 21: ...1611G4556 ...
Страница 24: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 46: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Страница 52: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan ...