Sleep timer
If the sleep timer is set, the room temperature is monitored and the operation is stopped auto-
matically. If the operation mode or the set temperature is change after the sleep timer is set, the
operation is continued according to the changed setting of the sleep timer from that time on.
• In the cooling operation mode
When the sleep timer is set, the setting temperature is increased 1.8°F (1°C). It increases the
setting temperature another 1.8°F (1°C) after 1 hour. After that, the setting temperature is not
changed and the operation is stopped at the setting time.
Set temperature rises
Ts: Set temperature
Stop of operation
Ts
+3.6
°F (
2°C)
Set
60 min
+1.8
°F (
1°C)
• In the heating operation mode
When the sleep timer is set, the setting temperature is decreased 1.8°F (1°C). It decreases
the setting temperature another 1.8°F (1°C) every 30 minutes. Upon lowering 7.2°F (4°C), the
setting temperature is not changed and the operation is stopped at the setting time.
Set
Ts
-3.6
°F (
2°C)
-1.8
°F (
1°C)
-5.4
°F (
3°C)
-7.2
°F (
4°C)
Ts: Set temperature
30 min
30 min
30 min
Stop of operation
Set temperature rises
¢
Weekly timer
On and off timer can be combined, and up to 4 reservations per day and 28 reservations per
week. Before setting the program, set the week and time of the air conditioner at first. If the week
and time are not set, the weekly timer will not operate correctly at the setting time.
5-2. Wired remote control
- (04-21) -
5. Timer operation control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание AOUG09LZAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 10 12 SR_CH01_AS024EF_03 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 10 12 SR_CH02_AS024EF_05 ...
Страница 33: ...3 TROUBLESHOOTING 2022 10 12 SR_CH03_AS024EF_07 ...
Страница 36: ......
Страница 117: ...4 CONTROL AND FUNCTIONS 2022 10 12 SR_CH04_AS024EF_03 ...
Страница 151: ...5 FILED WORKING 2022 10 12 SR_CH05_AS024EF_04 ...