5. INDOOR FAN CONTROL
The airflow can be switched in 5 steps such as Auto, Quiet, Lo, Me, Hi, while the indoor fan only runs.
When fan mode is set at [Auto], it operates on [Me] fan Speed.
01-05
2. FAN OPERATION
3. COOLING OPERATION
Switch the airflow [Auto], and the indoor fan motor will run according to a room temperature,
as shown in Fig4.
On the other hand, if switched in [Hi] [Quiet], the indoor motor will run at a constant airflow of [Cool]
operation modes Quiet, Lo, Me, Hi, as shown in Table 5.
( Fig.4 : Airflow change - over ( Cooling : Auto ) )
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts > 2°C
1°C > TR-Ts
2°C > TR-Ts > 1°C
=
TR-Ts > 2.5°C
=
1.5°C > TR-Ts
2.5°C > TR-Ts > 1.5°C
=
Hi mode
Me mode
Lo mode
1. Fan speed
( Table 5 : Indoor fan speed )
Operation mode
Air flow mode
Speed (rpm)
Cooling/ Fan
Heating
Dry
X zone: 550
J zone: 550
X zone: 550
J zone: 550
X zone: 550
J zone: 550
AS*G07KGTA AS*G09KGTA
AS*G12KGTA
4. DRY OPERATION
Refer to the Table 5.
During the dry mode operation, the fan speed setting can not be changed.
AS*G14KGTA
X zone: 590
J zone: 590
Hi
Hi
Me+
Me
Me
Lo
Lo
Quiet
Quiet
S-Lo
Cool air prevention
Powerful
Powerful
1200
1130
1040
950
790
620
550
400
1040
890
750
550
1110
1230
1160
1070
980
800
620
550
400
1100
920
750
550
1170
1290
1220
1140
1060
900
630
550
470
1130
950
790
550
1220
1330
1260
1160
1080
900
670
590
470
1220
1000
810
590
1290