03-03
Auto restart
Enables or disables automatic restart after a power interruption.
*Auto restart is an emergency function such as for power outage etc. Do not attempt to use
this function in normal operation. Be sure to operate the unit by remote controller or external
device.
Room temperature sensor switching
(Only for wired remote controller)
When using the wired remote controller temperature sensor, change the setting to "Both" (01).
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
*Remote controller sensor must be turned on by using the remote controller.
Function number
Setting value
Setting description
Factory setting
40
e
l
b
a
n
E
0
0
♦
e
l
b
a
s
i
D
1
0
Function number
Setting value
Setting description
Factory setting
42
ti
n
u
r
o
o
d
n
I
0
0
♦
h
t
o
B
1
0
Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed. Select the appropriate custom code.
External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to "Wired
remote controller" (01).
This function will only work if the func
tion setting 42 is set at "Both" (01).
Function number
Setting value
Setting description
Factory setting
44
A
0
0
♦
B
1
0
C
2
0
D
3
0
Function number
Setting value
Setting description
Factory setting
48
h
t
o
B
0
0
♦
01
Wired remote controller
Function number
Setting value
Setting description
Factory setting
46
00
Operation/Stop mode 1
♦
01
(Setting prohibited)
02
Forced stop mode
03
Operation/Stop mode 2