![Fujitsu AMUG24LMAS Скачать руководство пользователя страница 87](http://html.mh-extra.com/html/fujitsu/amug24lmas/amug24lmas_design-and-technical-manual_118227087.webp)
7. Additional charge calculation
7-1. Models: AOU24RGLX and AOU30RGLX
Refrigerant type
R410A
Refrigerant amount
lb oz
4 lb 10 oz
g
2,100
¢
Refrigerant charge
Total pipe length
ft
66 or less
98
131
164 (Max.)
0.43 oz/ft
(40 g/m)
m
20 or less
30
40
50 (Max.)
Additional charge
oz
0
14.1
28.2
42.3
g
0
400
800
1,200
7-2. Models: AOUG36LMAS1 and AOUG48LMAS1
Refrigerant type
R410A
Refrigerant amount
lb oz
9 lb 8 oz
g
4,300
¢
Refrigerant charge
Total pipe length
ft
98 or less
131
164
196
230 (Max.)
0.43 oz/ft
(40 g/m)
m
30 or less
40
50
60
70 (Max.)
Additional charge
oz
0
14.1
28.2
42.3
56.4
g
0
400
800
1,200
1,600