En-8

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

CAUSE and ACTION

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the panel due
to temperature changes.

During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling operation, a thin mist may be seen emitted from
the indoor unit. This results from the sudden Cooling of room air
by the air emitted from the air conditioner, resulting in condensa-
tion and misting.

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

During Heating operation, if the room temperature rises above
the set temperature, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the set the temperature for a higher setting.

During Heating operation, the unit will temporarily stop opera-
tion (between 2 and 16 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation,  DEFROST  will
be shown on the remote controller display.

The fan may operate at very low speed when the unit is monitor-
ing the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

6

6

6

6

6

6

NORMAL

FUNCTION

SPECIFICATIONS

If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the
electrical breaker, and consult with authorized service personnel.

REMOTE CONTROLLER (WIRED TYPE)

MODEL

POWER

DIMENSIONS & WEIGHT

HEIGHT [mm]

WIDTH [mm]

DEPTH [mm]

WEIGHT [g]

UTB- LB

DC 12 V

120

120

14

130

Symptom

Doesn’t operate at all:

Poor Cooling (or Heating)
performance:

See Page

3 to 5

Items to check

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the main power switch set to the OFF position?

Is the timer operating?

Is the air filter dirty?

Are the air conditioner’s intake grille or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

CHECK ONCE

MORE

Before requesting service, perform the following checks:

Содержание Airstage UTB- LB Series

Страница 1: ...CONDITIONER OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Remote Control Unit UTB LB REMOTE CONTROLLER WIRED TYPE TM English Deutsch Français Español Italiano EλληvIkά Русский Português ...

Страница 2: ...which if improperly performed might possibly result in personal harm to the user or damage to property This mark indicates procedures which if improperly performed might lead to the death or serious injury of the user DANGER Do not attempt to install this controller by yourself This controller contains no user serviceable parts Al ways consult authorized service personnel for repairs When moving c...

Страница 3: ...s not operating or when operating at very low speeds Vertical airflow swing operation Airflow direction Range of swing 1 1 to 3 2 2 to 4 3 2 to 4 4 1 to 4 All range Horizontal airflow swing operation Airflow direction Range of swing 1 1 to 5 All range 2 1 to 3 3 2 to 4 4 3 to 5 5 1 to 5 All range Fan speed setting Room temperature setting Vertical air direction adjustment 1 2 Swing operation Horiz...

Страница 4: ...seconds The WEEKLY 1 ON time starts flashing To set the WEEKLY timer For information concerning the WEEKLY TIMER function refer to p 7 OPERATING TIPS Press the START STOP button to stop the air conditioner and then proceed as follows 4 Set the WEEKLY 1 ON time Press repeatedly to adjust the time in 5 minute increments Press continuously to adjust the time in 10 minute incre ments 5 The day display...

Страница 5: ...sure to set the ON time first then the OFF time If either the ON time or the OFF time is not set correctly the timer will not operate properly The WEEKLY 2 settings cannot be set earlier than the WEEKLY 1 settings The WEEKLY 1 and WEEKLY 2 time spans cannot overlap 2 The earliest OFF time you can set is 5 minutes after the ON time The latest OFF time is 23 55 on the subsequent day 3 You do not nee...

Страница 6: ...AY OFF function refer to p 7 OPERATING TIPS Press the START STOP button to stop the air conditioner and then proceed as follows 1 Select 2 Select the number that corresponds to the selected day indicated by a code from 1 to 7 3 The DAY OFF caption appears on the display Stop the DAY OFF setting by press ing the DAY OFF button again Perform steps 1to 3in To set the WEEKLY timer P 3 Select the day t...

Страница 7: ...re is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During defrost ing the heating mode will be temporarily interrupted DEFROST will be shown on the remote controller display Fan speed When set to AUTO FAN speed Heating The fan will operate at very low speed when the...

Страница 8: ...occurred TROUBLESHOOTING Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle 1 If the operation lamp is on press the START STOP button to turn it off 2 Press SET TIME and TEMP DAY but tons at the same time for more than 3 seconds to start the self diagnosis check Error code Remote controller address 3 Press the SET TIME and TEMP DAY buttons at the same time for mo...

Страница 9: ...eration if the room temperature rises above the set temperature the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the set the temperature for a higher setting During Heating operation the unit will temporarily stop opera tion between 2 and 16 minutes as the Automatic Defrosting mode operates During Automatic Defrosting operat...

Отзывы: