ERROR
CONTENTS
1F
Transmission 3, Reset condition
ERROR CAUSE
4, Transmission adapter com-
REMEDY
ERROR
CODE
error
For 2-1), communication
with indoor unit restored.
For 2-2), normal communi-
cation restored between
transmission adapter con-
trol PC board and transmi-
ssion adapter communica-
tion PC board.
munication PC board or indoor
unit communication PC board
insertion faulty.
4,
Check insertion of communication
adapter communication PC board
and indoor unit communication PC
board.
5, Initialization not performed
after indoor unit address cha-
nged.
5,
Perform initialization.
6, PC board faulty
6,
1)If communication error generated
after parallel-parallel communication
error generated, replace PC boards
in following order, and check opera-
tion.
1
Transmission adapter communi-
cation PC board.
2
Transmission adapter control PC
board.
2)For other cases, replace PC boards
in following order, and check operation.
1
Indoor unit communication PC board
2
Indoor unit control PC board
21
Software error
(OUTPUT)
1, Generation condition
PC initialized by momentary
power interruption,etc.
When operation setting, modi-
fication, etc.
performed from central remote
controller and setting contents
reset.
1, Affect of extraneous noise
1-1 Check error continuity.
1) If error reset automatically, PC board
is normal.
therefore, remove noise sources near
central remote controller.
2)If error not reset automatically, check
following.
2, Corresponding operation
Error display. Only error code
display operation is possible.
Other operations are ineffective.
1-2 After ACL key pressed, or power
turned on again:
1) If error not generated again, PC board
is normal.
Therefore, remove noise sources near
control panel.
2)If error generated again, check follow-
ing, in addition to removing noise sources.
2, Power off or power supply
voltage abnormal.
2,
Check power supply voltage and
check operation after turning on
power.
3,PC board faulty.
3,
Replace PC boards in following
order, and check operation.
1
Transmission adapter control PC
board.
2
Operation panel PC board.
22
Software error
(INPUT)
1, Generation condition
Operation state of indoor
units memorized in transmiss-
ion adapter memory ab-
normal.
2, Corresponding operation
Error display. Central remote
controller operation is possible.
3, Reset condition
When contents of memory
memorized in transmission
adapter memory restored
to normal.
1, Affect of extraneous noise
1-1 Check error continuity.
1) If error reset automatically, PC board
is normal.Therefore, remove noise so-
urces near central remote controller.
2)If error not reset automatically, check
following.
1-2 After RESET key on transmission
adapter control PC board pressed,
or power turned on again:
1) If error not generated again, PC board
is normal. Therefore, remove noise
sources near operation panel.
2)If error generated again, check foll-
owing, in addition to removing noise
sources.
2, Transmission adapter cont-
2,
Replace transmission adapter co-
ntrol PC board.
rol PC board faulty.
– 113 –
Содержание AirStage AB12
Страница 2: ...Multi Air Conditioning System for Buildings VRF FREELY SELECTABLE MULTI TYPE SYSTEM SERVICE MANUAL 2 ...
Страница 76: ...MODELS AB30 AB36 AB45 AB54 RB UNIT For Heat Recovery only 7 2 LARGE CEILING TYPE 76 ...
Страница 77: ...MODELS AR7 AR9 AR12 AR14 AR18 RB UNIT For Heat Recovery only 7 3 COMPACT DUCT TYPE 77 ...
Страница 78: ...MODELS AR25 AR30 AR36 AR45 RB UNIT For Heat Recovery only 7 4 LOW STATIC PRESSURE DUCT TYPE 78 ...
Страница 79: ...MODELS AR36H AR45H AR60H RB For Heat Recovery only UNIT 7 5 HIGH STATIC PRESSURE DUCT TYPE 79 ...
Страница 80: ...MODELS AU7 AU9 AU12 AU14 AU18 RB UNIT For Heat Recovery only 7 6 COMPACT CASSETTE TYPE 80 ...
Страница 81: ...MODELS AU20 AU25 AU30 AU36 AU45 AU54 RB UNIT For Heat Recovery only 7 7 NEW CASSETTE TYPE 81 ...
Страница 82: ...MODELS 7 8 WALL MOUNTED TYPE AS14 20 24 30 82 ...
Страница 83: ...MODEL AOY90 7 9 OUTDOOR UNIT 83 ...
Страница 134: ...Models AOY90TPAMF 134 10 DISASSEMBLY ILLUSTRATION ...
Страница 135: ...Models AOY90TPAMF 135 ...
Страница 137: ...Models AOY90TPAMF 137 ...
Страница 142: ...Models ABY12TFAMF ABY14TFAMF 755 653 1 581 338 67 56 56 164 109 126 ABY18TFAMF ABY24TFAMF 142 ...
Страница 143: ...Models ABY12TFAMF ABY14TFAMF 416 8 1 417 385 868 771 488 472 443 473 ABY18TFAMF ABY24TFAMF 143 ...
Страница 149: ...Models ABY12TFAMF ABY14TFAMF 755 653 1 581 338 67 56 56 164 109 126 ABY18TFAMF ABY24TFAMF 142 ...
Страница 150: ...Models ABY12TFAMF ABY14TFAMF 416 8 1 417 385 868 771 488 472 443 473 ABY18TFAMF ABY24TFAMF 143 ...
Страница 155: ...Models ABY30TFAMF ABY36TFAMF ABY45TFAMF 407 876 1 505 408 435 434 506 3 ABY54TFAMF 148 ...
Страница 156: ...Models ABY30TFAMF ABY36TFAMF ABY45TFAMF 387 160 91 91 91 321 386 361 ABY54TFAMF 149 ...
Страница 157: ...Models ABY30TFAMF ABY36TFAMF ABY45TFAMF 63 876 2 385 868 763 227 321 387 436 424 684 438 ABY54TFAMF 150 ...
Страница 162: ...Models AUY20TFAMF AUY25TFAMF AUY30TFAMF AUY36TFAMF AUY45TFAMF AUY54TFAMF 155 ...
Страница 164: ...Models AUY25TLAMA AUY30TLAMA AUY36TLAMA AUY45TLAMA 157 ...
Страница 166: ...Models ARY25TLAMA ARY30TLAMA ARY36TLAMA ARY45TLAMA 57 56 109 67 338 164 67 57 56 126 109 234 143 138 108 159 ...
Страница 167: ...Models ARY25TFAMF ARY30TFAMF ARY36TFAMF ARY45TFAMF 160 ...
Страница 169: ... 162 Model ARY7TFAMF ARY9TFAMF ...
Страница 170: ...Model ARY7TFAMF ARY9TFAMF 163 875 ...
Страница 171: ...Model ARY12TFAMF ARY14TFAMF ARY18TFAMF 164 431 918 918 163 2 184 1 147 ...
Страница 172: ...Model ARY12TFAMF ARY14TFAMF ARY18TFAMF 165 ...
Страница 173: ...Model ARY12TFAMF ARY14TFAMF ARY18TFAMF 166 ...
Страница 175: ...422 126 477 109 477 477 109 164 422 10 75 45 117 3 338 1 338 2 56 2 477 56 1 Model ARY36TFAMF ARY45TFAMF ARY60TFAMF 168 ...
Страница 178: ...Model ASY20TFAMF ASY24TFAMF ARY30TFAMF 171 684 558 554 555 559 557 556 91 320 361 960 321 876 2 ...
Страница 179: ...Model ASY20TFAMF ASY24TFAMF ARY30TFAMF 172 91 876 1 407 1 407 2 407 3 69 ...
Страница 199: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jan 2002 Printed in Japan ...